GHS05
Health risk rating 2
Safety risk rating 5
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

229-912-9/6834-92-0

Name of the chemical

Disodium metasilicate

Concentration

1 - 5

Listed in

General Information

Version

3.0

Revision date

2021-01-27

Product name

Powercleaner 98

Emergency telephone

+31 (0)888-938839

Icons in SDS

GHS05 M004 M007 M009 T031

Company Information

company name

Zettex Europe B.V

e-mail address of the competent person responsible for the Safety Data Sheet

info@zettex.nl

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H290, H314

Hazard statements

Code

Statements

H290

May be corrosive to metals

Section 2

SECTION 2: Hazards identification

2.1 Classification of the substance or mixture

Classification

Hazard statements

see section 16 : H290 - May be corrosive to metals. H314 - Causes severe skin burns and eye damage.

Adverse physicochemical, human health and environmental effects

May be corrosive to metals. Causes severe skin burns and eye damage.

2.2 Label elements

Labelling

Hazard pictograms

GHS05

Signal word

Danger

Contains

Silicic acid (H2SiO3), disodium salt, pentahydrate

Precautionary statements

P101 - If medical advice is needed, have product container or label at hand. P102 - Keep out of reach of children. P280 - Wear eye protection, face protection, protective clothing, protective gloves. P301+P330+P331+P310 - IF SWALLOWED: rinse mouth. Do NOT induce vomiting. Immediately call a doctor. P303+P361+P353+P310 - IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. Immediately call a doctor. P305+P351+P338+P310 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a doctor. Child-resistant fastening : Applicable Tactile warning : Applicable

2.3 Other hazards

No additional information available

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.