Note: Ingredients listed on restricted chemical lists
EC/CAS
106-97-8
Name of the chemical
n-Butan, enthält 0,1% Butadien
Concentration
>=5-<10
General Information
Version
1.0
Revision date
2015-05-30
Product name
Kia A/C Evaporator Cleaner & Refresher / Part #UM090 CH035 Step 1 of 2
Emergency telephone
1-877-428-9937, 800-424-9300, 202-483-7616
Icons in SDS
Company Information
company name
Zep Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H280, H314, H318
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
H314
Causes severe skin burns and eye damage.
H318
Causes serious eye damage.
Section 2
SECTION 2: Hazards identification
OSHA Emergency Overview Appearance Aerosol containing a liquefied gas Colour colourless Odour alcohol-like, ammoniacal GHS Classification Gases under pressure Liquefied gas Skin corrosion Category 1A Serious eye damage Category 1
Signal word
Danger
Hazard statements
H280 Contains gas under pressure; may explode if heated. H314 Causes severe skin burns and eye damage.
Prevention
P260 Do not breathe dust or mist. P264 Wash skin thoroughly after handling. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection. P251 Pressurized container: Do not pierce or burn, even after use.
Response
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P303 + P361 + P353 IF ON SKIN (or hair): Remove/ Take off immediately all contaminated clothing. Rinse skin with water/ shower. P304 + P340 + P310 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Immediately call a POISON CENTER or doctor/ physician. P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/ physician. P363 Wash contaminated clothing before reuse.
Storage
P405 Store locked up. P410 + P403 Protect from sunlight. Store in a well-ventilated place. P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122 °F.
Disposal
P501 Dispose of contents/container in accordance with local regulation.
Potential health effects
Carcinogenicity: IARC No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC. ACGIH No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH.
2.1 Classification of the substance or mixture
Gases under pressure : Liquefied gas Skin corrosion : Category 1A Serious eye damage : Category 1