Note: Ingredients listed on restricted chemical lists
EC/CAS
67-63-0
Name of the chemical
Propan-2-ol
Concentration
>=5-<10
EC/CAS
112-34-5
Name of the chemical
2-(2-butoxyethoxy)ethanol
Concentration
>=5-<10
EC/CAS
106-97-8
Name of the chemical
n-Butan, enthält 0,1% Butadien
Concentration
>=5-<10
EC/CAS
770-35-4
Name of the chemical
1-Phenoxypropan-2-ol (7)
Concentration
>=1-<3
EC/CAS
7632-00-0
Name of the chemical
Sodium nitrite
Concentration
>=0.1-<1
General Information
Version
4.1
Revision date
2019-03-18
Product name
A00173 MSTY HD CARPET SPT REM_12CS 20N19
1.2.1 Relevant identified uses
Cleaner Carpet Care
Emergency telephone
1-877-428-9937, 800-424-9300, 202-483-7616
Icons in SDS
Company Information
company name
Zep Inc
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H280, H317, H319
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
Emergency Overview Appearance Aerosol containing a liquefied gas Colour clear Odour characteristic GHS Classification Gases under pressure Liquefied gas Eye irritation Category 2A Skin sensitisation Category 1
Signal word
Warning
Hazard statements
H280 Contains gas under pressure; may explode if heated. H317 May cause an allergic skin reaction. H319 Causes serious eye irritation.
Prevention
P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray. P264 Wash skin thoroughly after handling. P272 Contaminated work clothing should not be allowed out of the workplace. P280 Wear protective gloves/ eye protection/ face protection. P251 Pressurized container: Do not pierce or burn, even after use.
Response
P302 + P352 IF ON SKIN: Wash with plenty of water. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P333 + P313 If skin irritation or rash occurs: Get medical advice/ attention. P337 + P313 If eye irritation persists: Get medical advice/ attention. P363 Wash contaminated clothing before reuse.
Storage
P410 + P403 Protect from sunlight. Store in a well-ventilated place. P412 Do not expose to temperatures exceeding 50 °C/ 122 °F.
Disposal
P501 Dispose of contents/container in accordance with local regulation.
2.1 Classification of the substance or mixture
Gases under pressure : Liquefied gas Eye irritation : Category 2A Skin sensitisation