Note: Ingredients listed on restricted chemical lists
EC/CAS
811-97-2
Name of the chemical
1,1,1,2-Tetrafluoroethane
Concentration
>=50-<60 1,2-
EC/CAS
68411-46-1
Name of the chemical
benzenamine, N-phenyl-, reaction products with 2,4,4-trimethylpentene (BPTMP)
Concentration
4- >=0.3-<1
EC/CAS
68937-41-7
Name of the chemical
Isopropylphenyl phosphate
Concentration
>=0.1-<0.25
General Information
Revision date
2025-06-18
Product name
에어컨 누출 차단 및 냉매 강화제 4IN1 A/C LEAK SEALANTProduct code : 0892 764 330
Icons in SDS
Company Information
company name
Würth Korea Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
prodsafe@wuerth.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H229, H412
Hazard statements
Code
Statements
H229
Pressurized container: may burst if heated
H412
Harmful to aquatic life with long lasting effects
Section 2
SECTION 2: Hazards identification
GHS Classification GHS Classification Long-term (chronic) aquatic Category 3 hazard Aerosols Category 3
Hazard pictograms
Not applicable
Signal word
Warning
Hazard statements
H229 Pressurised container: May burst if heated. H412 Harmful to aquatic life with long lasting effects.
Prevention
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P251 Do not pierce or burn, even after use. P261 Avoid breathing spray. P271 Use only outdoors or in a well-ventilated area. P273 Avoid release to the environment.
Storage
P410 + P412 Protect from sunlight. Do not expose to tempera- tures exceeding 50 °C/ 122 °F.
Disposal
P501 Dispose of contents/ container according to waste-related laws
Other hazards which do not result in classification
May displace oxygen and cause rapid suffocation.
2.1 Classification of the substance or mixture
Long-term (chronic) aquatic : Category 3 hazard Aerosols