Note: Ingredients listed on restricted chemical lists
EC/CAS
232-475-7/8050-09-7
Name of the chemical
Rosin
Concentration
>=2,3-<=3
General Information
Revision date
2019-06-05
Product name
WSW SC L0 / WSW SC M1 - Solder Wire lead free Sn0.7Cu Flux L0/M1
CAS No.
8050-09-7
1.2.1 Relevant identified uses
remark
supplier name
Weller Tools GmbH
Emergency telephone
GIZ Mainz +49 6131 - 19240 (German, English, French
Icons in SDS
Company Information
company name
Weller Tools GmbH
e-mail address of the competent person responsible for the Safety Data Sheet
info@weller-tools.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H317, H334
Hazard statements
Code
Statements
H317
May cause an allergic skin reaction
H334
May cause allergy or asthma symptoms or breathing difficulties if inhaled
Section 2
Health hazards
Skin Sens. 1 Resp. Sens. 1
Hazard statements
H317 May cause an allergic skin reaction. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317 May cause an allergic skin reaction. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.
2.2 Label elements
Labelling according to Regulation (EC) No. 1272/2008 [CLP]
Hazard pictograms
GHS07 GHS08
Signal word
Danger
Prevention
P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P280 Wear protective gloves/protective clothing/eye protection/face protection. P285 In case of inadequate ventilation wear respiratory protection.
Response
P302 + P352 IF ON SKIN: Wash with plenty of water/. P304 + P341 IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. P333 + P313 If skin irritation or rash occurs: Get medical advice/attention. 9.1
Storage
P403 + P235 Store in a well-ventilated place. Keep cool.
Supplemental label elements
health hazard properties EUH066 Repeated exposure may cause skin dryness or cracking.
Potential health effects
Prolonged or repeated skin contact may cause removal of natural fat from the skin resulting in dermatitis (skin inflammation). Inhalation of dust may cause irritation of the respiratory system.
Other physicochemical hazards
The vapour of the product is heavier than air and may accumulate below ground level, in pits, channels and basements in higher concentration.
Other hazards
People who suffer from skin sensitazion problems, asthma, allergies, chronic or recurring respiratory illnesses should not be deployed in any process using this preparation. Processing vapours can irritate the respiratory tracts, skin and eyes.