Unimig Hyperarc 16TC

Welding Guns of Australia Pty Ltd

Revision date : 2020-12-29

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS07 GHS08
Health risk rating 5
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

124-38-9

Name of the chemical

Carbon dioxide CO2

Concentration

N/A

EC/CAS

630-08-0

Name of the chemical

Kohlenmonoxid

Concentration

N/A

EC/CAS

7439-96-5

Name of the chemical

Manganese

Concentration

N/A

EC/CAS

7440-02-0

Name of the chemical

Nickel

Concentration

N/A

EC/CAS

7440-47-3

Name of the chemical

Chromium; chromic acid and its salts

Concentration

N/A

EC/CAS

10028-15-6

Name of the chemical

Ozone

Concentration

N/A

General Information

Revision date

2020-12-29

Product name

Unimig Hyperarc 16TC

1.2.1 Relevant identified uses

MMA welding electrode low hydrogen twin coated suitable for all positions except vertical down

Icons in SDS

Company Information

company name

Welding Guns of Australia Pty Ltd

e-mail address of the competent person responsible for the Safety Data Sheet

sales@unimig.com.au

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H332, H350

Hazard statements

Code

Statements

H332

Harmful if inhaled

Section 2

2.1 Classification of the substance or mixture

Poisons Schedule Not Applicable

Classifications

1] Acute Toxicity (Inhalation) Category 4, Carcinogenicity Category 1A 1. Classified by Chemwatch; 2. Classification drawn from HCIS; 3. Classification drawn from Regulation (EU) No 1272/2008 - Legend: Annex VI

Signal word

Danger

Hazard statements

H332 Harmful if inhaled. H350 May cause cancer.

Prevention

P201 Obtain special instructions before use. P271 Use only outdoors or in a well-ventilated area. P281 Use personal protective equipment as required. P261 Avoid breathing dust/fumes.

Response

P308+P313 IF exposed or concerned: Get medical advice/attention. P312 Call a POISON CENTER or doctor/physician if you feel unwell. P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Storage

P405 Store locked up.

Disposal

P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.