Note: Ingredients listed on restricted chemical lists
EC/CAS
67-63-0
Name of the chemical
Propan-2-ol
Concentration
≥10-≤30
General Information
Version
1.02
Revision date
2022-10-19
Product name
Activator F Spray
1.2.1 Relevant identified uses
Aerosol product-Activators-Surface treatment products
supplier name
WEICON GmbH & Co. KG
Emergency telephone
+1 866 928 0789
Icons in SDS
Company Information
company name
WEICON Canada Inc
e-mail address of the competent person responsible for the Safety Data Sheet
msds@weicon.de, info@weicon.ca
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H280, H319, H336
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
FLAMMABLE AEROSOLS - Category 1 GASES UNDER PRESSURE - Compressed gas EYE IRRITATION - Category 2A SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Narcotic effects) - Category 3
Signal word
Danger
Hazard statements
H222 - Extremely flammable aerosol. H280 - Contains gas under pressure; may explode if heated. H319 - Causes serious eye irritation. H336 - May cause drowsiness or dizziness.
Prevention
P280 - Wear eye or face protection. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P211 - Do not spray on an open flame or other ignition source. P271 - Use only outdoors or in a well-ventilated area. P261 - Avoid breathing dust or mist. P264 - Wash thoroughly after handling. P251 - Do not pierce or burn, even after use.
Response
P304 + P340, P312 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor if you feel unwell. P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 - If eye irritation persists: Get medical advice or attention.
Storage
P405 - Store locked up. P410 + P403 - Protect from sunlight. P410 + P412 - Do not expose to temperatures exceeding 50 °C/122 °F. P403 + P233 - Store in a well-ventilated place. Keep container tightly closed.
Disposal
P501 - Dispose of waste according to applicable legislation.