General Information

Version

2.0

Revision date

2026-06-02

Product name

500465 Acetate C-6 (Hexyl Acetate)

Substance name

500465 Acetate C-6 (Hexyl Acetate)

Chemical name

Hexyl Acetate

CAS No.

142-92-7

1.2.1 Relevant identified uses

Perfumery ingredient

supplier name

Vigon International, LLC

Emergency telephone

+44 1235 239670, +1 800 579 7421, +65 3158 1074, 1235 239671, +44 1865 407333, +1 202 464 2554

Icons in SDS

GHS02 M004 M009 M010 M017 T017

Company Information

company name

Vigon International, LLC

e-mail address of the competent person responsible for the Safety Data Sheet

regulatory@vigon.com

GHS Information

Signal word

Warning

Hazard Codes

Hazard statements (CLP)

H226, H401

Hazard statements

Code

Statements

H226

Flammable liquid and vapour

Section 2

SECTION 2: Hazards identification

Classification of the substance or mixture GHS US classification Flam. Liq. 3 Aquatic Acute 2 H226 Flammable liquid and vapour H401 Toxic to aquatic life

Hazard statements

see section 16 : H226 - Flammable liquid and vapour H401 - Toxic to aquatic life

2.2 Label elements

GHS US labelling

Signal word

Warning

Precautionary statements

P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 - Keep container tightly closed. P240 - Ground/Bond container and receiving equipment. P241 - Use explosion-proof electrical, lighting, ventilating equipment. P242 - Use non-sparking tools. P243 - Take action to prevent static discharges. P273 - Avoid release to the environment. P280 - Wear eye and face protection, protective gloves. P303+P361+P353 - If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P370+P378 - In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish. P403+P235 - Store in a well-ventilated place. Keep cool. P501 - Dispose of contents and/or container to to an approved waste disposal plant. 2.3. Hazards associated with known or reasonably anticipated uses No additional information available

Other hazards which do not result in classification

This material may have the potential to be ignited by static electricity during handling or processing. Use proper grounding techniques when handling this product to avoid electrostatic charges. A detailed static evaluation is recommended for liquid handling/processing operation to determine the potential for generating and accumulating static charge. Reference NFPA 77 “Recommended Practice on Static Electricity” for further safe handling practices. 2.5. Unknown acute toxicity No additional information available

2.1 Classification of the substance or mixture

GHS US classification Flam. Liq. 3 H226 Flammable liquid and vapour. Aquatic Acute 2 H401 Toxic to aquatic life. Full text of hazard classes and H-statements : see section 16 2.2. Label elements GHS US labelling Hazard pictograms (GHS US) : Signal word (GHS US) : Warning Hazard statements (GHS US) : H226 - Flammable liquid and vapour H401 - Toxic to aquatic life Precautionary statements (GHS US) : P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 - Keep container tightly closed. P240 - Ground/Bond container and receiving equipment. P241 - Use explosion-proof electrical, lighting, ventilating equipment. P242 - Use non-sparking tools. P243 - Take action to prevent static discharges. P273 - Avoid release to the environment. P280 - Wear eye and face protection, protective gloves. P303+P361+P353 - If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P370+P378 - In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish. P403+P235 - Store in a well-ventilated place. Keep cool. P501 - Dispose of contents and/or container to to an approved waste disposal plant. 2.3. Hazards associated with known or reasonably anticipated uses No additional information available 2.4. Hazards not otherwise classified Other hazards which do not result in classification : This material may have the potential to be ignited by static electricity during handling or processing. Use proper grounding techniques when handling this product to avoid electrostatic charges. A detailed static evaluation is recommended for liquid handling/processing operation to determine the potential for generating and accumulating static charge. Reference NFPA 77 “Recommended Practice on Static Electricity” for further safe handling practices. 2.5. Unknown acute toxicity No additional information available

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.