Permanent magnet, tinned

VACUUMSCHMELZE GmbH & Co. KG

Revision date : 2015-07-20

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS07 GHS08
Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7440-48-4

Name of the chemical

Cobalt, Metall (2020/217)

Concentration

N/A

EC/CAS

7440-50-8

Name of the chemical

Copper

Concentration

N/A

EC/CAS

7440-67-7

Name of the chemical

Zirconium and its compounds, with the exception of the substances listed under reference number 50 in Annex III, and the zirconium lakes, pigments or salts of the colouring agents when listed in Annex IV

Concentration

N/A

EC/CAS

7440-31-5

Name of the chemical

Tin

Concentration

N/A

EC/CAS

231-158-0

Name of the chemical

Cobalt, Metall (2020/217)

Concentration

N/A

EC/CAS

231-159-6

Name of the chemical

Copper (nano) [INCI] (11), Colloidal Copper (nano) [INCI] (11)

Concentration

N/A

EC/CAS

231-176-9

Name of the chemical

Zirconium and its compounds, with the exception of the substances listed under reference number 50 in Annex III, and the zirconium lakes, pigments or salts of the colouring agents when listed in Annex IV

Concentration

N/A

General Information

Revision date

2015-07-20

Product name

Permanent magnet, tinned

1.2.1 Relevant identified uses

PERMANENT MAGNETS e.g. in motors, generators, sensors, E-Mobility

Emergency telephone

via (**49) 6181/38-0

Icons in SDS

Company Information

company name

VACUUMSCHMELZE GmbH & Co. KG

e-mail address of the competent person responsible for the Safety Data Sheet

datasheet@vacuumschmelze.com

Section 2

CLP CLASSIFICATION

CLP-Regulation) Not applicable Our semi-finished and finished products constitute manufactured articles under the terms of the REACH Regulation (EC) No. 1907/2006. For articles there is no obligation to classify acc. to CLP -Regulation. • 2.2 Labelling according to Regulation (EC) No 1272/2008 Labelling according to Regulation (EC) No 1272/2008 (CLP-Regulation): Not applicable • Additional VAC information: In the case of dust-producing processing, we recommend observance of the following warnings : The hazard statements result from the ingredients (composition) of the permant magnets and the applied coating.

Additional information

See also Chapter 11

Hazard statements

See also 'Other hazards' (chapter 2.3)) Harmful if swallowed. May cause allergy or asthma symptoms or breathing difficulties if inhaled. May cause an allergic skin reaction. May cause cancer. Route of exposure: Inhalative. Suspected of damaging fertility or the unborn child. May cause long lasting harmful effects to aquatic life.

Precautionary statements

Do not breathe dust/fume/gas/mist/vapors/spray. In case of inadequate ventilation wear respiratory protection. Use personal protective equipment as required. Avoid release to the environment. Do not eat, drink or smoke when using this product. If skin irritation occurs: Get medical advice/attention. Store locked up.

2.3 Other hazards

Dry mechanical processing of rare earth permanent magnet alloys is only permitted under special safety precautions because dusts which are capable of self-heating or pyrophorous dusts with a tendency to explode may be produced. In the case of wet mechanical processing the watery processing medium reacts with the magnet wear and may form hydrogen already at room temperature. Attention: Formation of Ex-atmospheres possible! Part of the resulting hydrogen is stored in the material. The resulting processing sludges must be kept under a protective liquid because drying out sludges are capable of self-heating or may react pyrophorously. In this case the stored hydrogen volume burns off with flames. Attention: Magnetized parts generate magnetic fields and are able to attract magnetizable materials. This may result in injury during handling of magnets. Electronic devices and measuring tools may be changed in calibration or damaged by the high magnetic field strength. Please keep magnetized magnets away from computers, displays and magnetic storage devices. Especially people with heart pacemakers must keep away from magnetic fields.

PBT Substances

Not applicable

vPvB Substances

Not applicable

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.