USG Acoustical Ceiling Panels and Tiles - ECLIPSE ClimaPlus with Aegis Microbe Shield

USG Interiors, Inc

Revision date : 2003-10-07

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
Health risk rating
Safety risk rating
Environmental risk rating

Note: Ingredients listed on restricted chemical lists

EC/CAS

16389-88-1

Name of the chemical

dolomite

Concentration

<1

EC/CAS

9005-25-8

Name of the chemical

Starch

Concentration

>75

EC/CAS

27668-52-6

Name of the chemical

Dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride

Concentration

<1

EC/CAS

1332-58-7

Name of the chemical

kaolin

Concentration

<2

EC/CAS

14808-60-7

Name of the chemical

Silica, crystalline

Concentration

<1

EC/CAS

7429-90-5

Name of the chemical

Aluminium

Concentration

<2

EC/CAS

24937-78-8

Name of the chemical

ethylene-vinyl acetate copolymer wax

Concentration

<1

General Information

Revision date

2003-10-07

Product name

USG Acoustical Ceiling Panels and Tiles - ECLIPSE ClimaPlus with Aegis Microbe Shield

Product Synonyms

Mineral wool acoustical ceiling panels

Chemical name

Mixture of slag wool and minerals. Ceiling panels and tiles are products considered not to be

Manufacturer Name

USG Interiors, Inc

Emergency telephone

1 (800) 507-8899

Icons in SDS

Company Information

company name

USG Interiors, Inc

Section 2

SECTION 2: Hazards identification

INFORMATION FOR HANDLING AND IDENTIFICATION OF CHEMICAL HAZARDS

NFPA Ratings

HEALTH 0 0 = Minimal Hazard HIMS Ratings: * 1 = Slight Hazard FLAMMABILITY 0 Health: 0 Health: *0 2 = Moderate Hazard Fire: 0 Fire: 0 PHYSICAL HAZARD 0 3 = Serious Hazard Reactivity: 0 Reactivity: 0 PERSONAL PROTECTION E 4 = Severe Hazard Personal Protection: Use eye protection. Use gloves and NIOSH/MSHA-approved respiratory protection when required. *Respirable crystalline silica can cause lung disease and/or cancer. EMERGENCY OVERVIEW This product is not expected to produce any unusual hazards during normal use. Exposure to high dust levels may irritate the skin, eyes, nose, throat, or upper respiratory tract. Man-made mineral fibres have been classified by the European Union as irritating to skin (R:38).

Potential health effects

ACUTE: The components of acoustical ceiling panels and tiles are bound in a cementitious matrix. When panels are cut or trimmed, especially with power tools, the resulting dust may cause transitory mechanical irritation to skin, eyes or respiratory tract. Eyes: Airborne dust or direct contact can cause mechanical irritation of eyes. If burning, redness, itching, pain or other symptoms persist or develop, consult physician. Skin: Direct, prolonged or repeated contact with the skin can cause temporary irritation and itchiness. Rubbing of this product against the skin can result in abrasions. If irritation persists, consult a physician. Inhalation: Inhalation of dust can irritate the nose, throat, and the upper respiratory tract. Persons subjected to large amounts of this dust will be forced to leave area because of nuisance conditions such as coughing, sneezing and nasal irritation. Labored breathing may occur after excessive inhalation. If respiratory symptoms persist, consult physician. Ingestion: Unlikely to occur, but if ingested may cause temporary irritation to the gastrointestinal tract, especially the throat and stomach. CHRONIC: Inhalation: Prolonged and repeated exposure to airborne free respirable crystalline silica can result in lung disease (i.e., silicosis) and/or lung cancer. The development of silicosis may increase the risks of additional health effects. The risk of developing silicosis is dependent upon the exposure intensity and duration. Exposures to respirable crystalline silica are not expected during the normal use of this product; however, actual levels must be determined by workplace hygiene testing. The concentration of respirable crystalline silica measured in airborne dust samples was below the detection limit using NIOSH Method 7500 in industrial hygiene testing of workers installing USG Acoustical Ceiling Panels for an 8 hour work day. Slag wool fiber has been classified as “not classifiable as to its carcinogenicity to humans” (Group 3) by the International Agency for Research on Cancer (IARC). SECTION 3 HAZARD IDENTIFICATION (continued) CHRONIC (continued): Eyes: No known effects Skin: No known effects. Ingestion: No known effects. TARGET ORGANS: Eyes, skin and nose, throat & respiratory system.

Principle Routes of Exposure

Inhalation, eyes and skin contact MEDICAL CONDITIONS WHICH MAY BE AGGRAVATED: Pre-existing upper respiratory and lung diseases such as, but not limited to, bronchitis, emphysema and asthma. Pre-existing skin diseases such as, but not limited to, rashes and dermatitis.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.