Note: Ingredients listed on restricted chemical lists
EC/CAS
64742-95-6
Name of the chemical
Solvent naphtha (petroleum), light arom
Concentration
N/A
EC/CAS
106-97-8
Name of the chemical
n-Butan, enthält 0,1% Butadien
Concentration
N/A
EC/CAS
75-28-5
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
N/A
EC/CAS
265-199-0
Name of the chemical
Solvent naphtha (petroleum), light arom
Concentration
N/A
EC/CAS
203-448-7
Name of the chemical
n-Butan, enthält 0,1% Butadien
Concentration
N/A
EC/CAS
200-857-2
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
N/A
General Information
Revision date
2015-04-22
Product name
UNIPAK Rust Penetrant
1.2.1 Relevant identified uses
rust-dissolver and corrosion protection
1.2.2. Uses advised against
-
Icons in SDS
Company Information
company name
Unipak A/S
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H229
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
2.1 Classification of the substance or mixture
Aerosol 1, // H229, H222 See full text of H/R-phrases in section 2.2.
Classification (DPD)
F+; R12
Signal word
Danger!
Hazard statements
Extremely flammable aerosol. (H222) Pressurised container: May burst if heated. (H229) General -
Prevention
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. (P210) Do not spray on an open flame or other ignition source. (P211)
Precautionary statements
Do not pierce or burn, even after use. (P251)
Storage
Store in a well-ventilated place. (P403) Protect from sunlight. Do no expose to temperatures exceeding 50°C/122°F. (P410+P412)
Disposal
Identity of the substances primarily responsible for the major health hazards -
Additional information
Additional warnings - VOC -