Lightning Activator

TRANSTAR AUTOBODY TECHNOLOGIES

Revision date : 2015-01-26

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS02 GHS08 GHS06
Health risk rating 5
Safety risk rating 3
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

123-86-4

Name of the chemical

acetic acid, butyl ester

Concentration

150 ppm

EC/CAS

64742-95-6

Name of the chemical

Solvent naphtha (petroleum), light arom

Concentration

200 ppm

EC/CAS

98-56-6

Name of the chemical

4-Chloro-alpha,alpha,alpha-trifluorotoluene

Concentration

5 to 10%

General Information

Revision date

2015-01-26

Product name

Lightning Activator

1.2.1 Relevant identified uses

Activator. For Professional and Industrial Use Only

Emergency telephone

800-424-9300, 001-703-527-3887

Icons in SDS

GHS02 GHS06 GHS08

Company Information

company name

TRANSTAR AUTOBODY TECHNOLOGIES

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H225, H315, H317, H331, H334, H336, H350

Hazard statements

Code

Statements

H225

Highly Flammable liquid and vapour

Section 2

SECTION 2: Hazards identification

Classifications

Flammable liquid Flash point < 23°C and initial boiling point > 35°C (95°F) Inhalation Toxicity Acute Tox. 3 Gases>500+<=2500ppm, Vapors>2+<=10mg/l, Dusts&mists>0.5+<=1mg/l Skin corrosive Reversible adverse effects in dermal tissue, Draize score: >= 2.3 < 4.0 or persistent inflammation Respiratory sensitizer Respiratory sensitizer Skin sensitizer Skin sensitizer Carcinogen 1B Presumed Human Carcinogen, Based on demonstrated animal carcinogenicity Organ toxin single exposure Transient target organ effects- Narcotic effects- Respiratory tract irritation

Precautionary statements

H225 Highly flammable liquid and vapor P101 If medical advice is needed, have H315 Causes skin irritation product container or label at hand H317 May cause an allergic skin P102 Keep out of reach of children reaction P103 Read label before use H331 Toxic if inhaled P201 Obtain special instructions before use H334 May cause allergy or asthma P202 Do not handle until all safety symptoms or breathing difficulties precautions have been read and if inhaled understood H336 May cause drowsiness or P210 Keep away from heat, sparks, open dizziness flames and hot surfaces - No smoking H350 May cause cancer P233 Keep container tightly closed P240 Ground and bond container and receiving equipment P241 Use explosion-proof electrical, ventilating, lighting and motorized equipment P242 Use only non-sparking tools P243 Take precautionary measures against static discharge P261 Avoid breathing dust, mist, vapors and spray P264 Wash contacted skin thoroughly after handling P271 Use only outdoors or in a well-ventilated area P272 Contaminated work clothing should not be allowed out of the workplace P280 Wear protective gloves, protective clothing, eye protection, face protection and respiratory protection. P281 Use personal protective equipment as required P285 In case of inadequate ventilation wear respiratory protection P311 Call a POISON CENTER or doctor P321 Specific treatment (see first aid instructions on SDS) P363 Wash contaminated clothing before reuse P303+P361+P353 IF ON SKIN (or hair): Immediately take off all contaminated clothing. Wash skin with soap and water. P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing P308+P313 IF exposed or concerned: Get medical advice P333+P313 If skin irritation or a rash occurs: Get medical advice P342+P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor P370+P378 In case of fire: Use dry chemical, CO2, foam or water fog to extinguish P405 Store locked up P403+P235 Store in a well ventilated place. Keep cool P501 Dispose of contents and container in accordance with local, regional, national and international regulations. Danger

2.3 Other hazards

None known

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.