Note: Ingredients listed on restricted chemical lists
General Information
Revision date
2017-06-02
Product name
AMP-95
Chemical name
Amino Alcohol
1.2.1 Relevant identified uses
Tower Metalworking Fluids 4300 South Tripp Ave Chicago, IL 60632
Emergency telephone
(800) 424-9300
Icons in SDS
Company Information
company name
Tower Metalworking Fluids
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H227, H315, H318
Hazard statements
Code
Statements
H227
Combustible liquid
Section 2
2.1 Classification of the substance or mixture
This material is classified as hazardous under OSHA regulations (29CFR 1910.1200) (Hazcom 2012). Flammable liquid: Category 4 Skin irritation: Category 2 Serious eye damage: Category 1
Signal word
DANGER
Hazard statements
H227 Combustible Liquid H315 Causes skin irritation. H318 Causes serious eye damage.
Prevention
P210 Keep away from sparks, open flames, hot surfaces. No smoking. P264 Wash contact area thoroughly after handling. P280 Wear chemical resistant gloves, goggles and face shield.
Response
P302 + P352 IF ON SKIN: Wash with plenty of water and mild soap. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P332 + P313 If skin irritation occurs: Get medical advice/attention. P362 + P364 Take off contaminated clothing and wash it before reuse. P370+P378 In case of fire: Use water fog, foam, dry chemical or carbon dioxide to extinguish.
Storage
P403+P235 Store in a well-ventilated place. Keep cool.
Disposal