Note: Ingredients listed on restricted chemical lists
EC/CAS
270-990-9/68512-91-4
Name of the chemical
Hydrocarbons, C3-4-rich, petroleum distillate
Concentration
N/A
EC/CAS
203-450-8
Name of the chemical
1,3-Butadien
Concentration
N/A
General Information
Revision date
2014-01-27
Product name
PROPANE
supplier name
TOTAL BELGIUM
Emergency telephone
Official National Emergency Number
Icons in SDS
Company Information
company name
TOTAL BELGIUM
e-mail address of the competent person responsible for the Safety Data Sheet
rm.be-reach-belgium-msds@total.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
2.1 Classification of the substance or mixture
REGULATION (EC) No 1272/2008 For the full text of the H-Statements mentioned in this Section, see Section 2.2. Flammable gases*** - Category 1*** - H220*** Gases under pressure*** - Liquefied gas*** - H280*** DIRECTIVE 67/548/EEC or 1999/45/EC For the full text of the R-phrases mentioned in this Section, see Section 16. F+; R12***
2.2 Label elements
Labelled according to REGULATION (EC) No 1272/2008*** EC-No 270-990-9***
Signal word
DANGER***
Hazard statements
H220 - Extremely flammable gas***
Precautionary statements
P102 - Keep out of reach of children P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely P381 - Eliminate all ignition sources if safe to do so P403 - Store in a well-ventilated place*** Single packages : Transport labelling is permitted. Regulation (EC) No 1272/2008, ANNEX I, 1.3.2 : Derogations from labelling requirements for special cases. Gas containers intended for propane, butane or liquefied petroleum gas (LPG).***
2.3 Other hazards
Physical-Chemical Properties Extremely flammable. May form explosive mixtures with air. In case of a leak, this gas travels along the ground since it is HEAVIER THAN AIR, and may ACCUMULATE IN LOW AREAS IF VENTILATION IS INSUFFICIENT with a risk of remote ignition. Accidental intense heating (in case of fire for example) of a container filled with this gas can lead to bursting and spreading of the product whose vapours may ignite causing deflagration or explosion.***
Potential health effects
In the gaseous phase: may have a slight anaesthetic effect and/or an asphyxiating effect as it reduces the oxygen content in the air. Contact with product may cause frostbite.***