General Information
Version
1.0
Revision date
2025-01-31
Product name
Phenyl Isothiocyanate
CAS No.
103-72-0
Emergency telephone
+81-3-5640-8878, +81-3-5640-8902
Icons in SDS
Company Information
company name
TOKYO CHEMICAL INDUSTRY CO., LTD
e-mail address of the competent person responsible for the Safety Data Sheet
globalbusiness@tcichemicals.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H227, H301, H314, H410
Hazard statements
Code
Statements
H227
Combustible liquid
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Flammable liquids : Category 4 Acute toxicity (Oral) : Category 3 Skin corrosion/irritation : Category 1B Serious eye damage/eye irritation : Category 1 Short-term (acute) aquatic hazard : Category 1 Long-term (chronic) aquatic hazard
Signal word
Danger
Hazard statements
Combustible liquid. Toxic if swallowed. Causes severe skin burns and eye damage. Very toxic to aquatic life with long lasting effects.
Prevention
Keep away from heat/ sparks/ open flames/ hot surfaces. No smoking. Wash skin thoroughly after handling. Do not eat, drink or smoke when using this product. Avoid release to the environment. Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
IF SWALLOWED: Immediately call a POISON CENTER/ doctor. Rinse mouth. IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/ doctor. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/ doctor. Wash contaminated clothing before reuse. In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extin- guish. Collect spillage.
Storage
Store in a well-ventilated place. Keep cool. Store locked up.
Disposal
Dispose of contents/ container to an approved waste disposal plant.
Other hazards which do not result in classification
No data available