Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-44-0
Name of the chemical
Carbon black
Concentration
N/A
General Information
Revision date
2013-08-19
Product name
Tenax -A carbon fiber - continuous filament or chopped, with sizing
CAS No.
7440-44-0
1.2.1 Relevant identified uses
Continuous or Chopped Carbon Fiber Filament with Surface Treatment Method of operation
Icons in SDS
Company Information
company name
Toho Tenax America, Inc
e-mail address of the competent person responsible for the Safety Data Sheet
jcarling@tohotenaxus.com, mklemmer@tohotenaxus.com
Section 2
SECTION 2: Hazards identification
Emergency Overview The hazards of this product are associated mainly with its processing. Processing para-aramid products can release respirable dust and respirable fibre particulate. Dust may form explosive mixture in air. Prolonged inhalation of respirable dust and respirable fibre particulate at high concentrations can cause lung damage. High concentrations of dust can irritate eyes, nose and respiratory system and cause coughing and sneezing. Continual rubbing of fibre particulates and dust on the skin can cause a transitory, mild irritation with redness or itching. Physical and chemical properties Form : Nonwoven fabric, woven fabric, fibres, yarn Color : gold Odor : odourless Melting point/range : not applicable Boiling point/boiling range : not applicable Specific gravity : 1.44 - 1.45 at 20 °C (68 °F) Water solubility : insoluble Viscosity : no data available Viscosity, kinematic : no data available 1 / 6 Article Information Sheet KEVLAR® Para-aramid Version 2.1 Revision Date: 11/14/2013 Ref. 150000002634 Stability and reactivity Incompatibility : Strong acids and strong bases Hazardous decomposition : Carbon dioxide products nitrogen oxides (NOx) , Hydrogen cyanide (gaseous) , Ammonia, anhydrous Aldehydes, Hydrocarbons INFORMATION ON INGREDIENTS Exposure limits may be applicable for the following : Component CAS-No. Concentration Para-aramid fiber 100 % Para-aramid 26125-61-1 FIRST AID MEASURES Description of first aid measures General advice : No hazards which require special first aid measures. If symptoms persist, call a physician. If irritation occurs, flush area thoroughly with water. FIREFIGHTING MEASURES 2 / 6 Article Information Sheet KEVLAR® Para-aramid Version 2.1 Revision Date: 11/14/2013 Ref. 150000002634 Extinguishing media Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Special hazards arising from the article Specific hazards during : Hazardous decomposition products formed under fire conditions. firefighting Advice for firefighters Special protective equipment : Wear self contained breathing apparatus for fire fighting if necessary. for firefighters ACCIDENTAL RELEASE MEASURES Personal precautions, protective equipment and emergency procedures Personal precautions : None. Environmental precautions : Do not let product enter drains. Methods and materials for containment and cleaning up Methods for cleaning up : Avoid dust formation. Clean up dusts and fibres with high efficiency particulate air (HEPA) filtered vacuum equipment, or by wet cleaning. 3 / 6 Article Information Sheet KEVLAR® Para-aramid Version 2.1 Revision Date: 11/14/2013 Ref. 150000002634 HANDLING AND STORAGE Precautions for safe handling Advice on safe handling : Avoid dust formation. Exposure to fibre fly, dust and decomposition products of spinfinishes should be avoided by ventilation and/or vacuum cleaning. Do not touch moving threadlines. Entanglement with this fibre can severely cut or even sever fingers. Conditions for safe storage, including any incompatibilities Requirements for storage : Keep away from direct sunlight. areas and containers EXPOSURE CONTROLS/PERSONAL PROTECTION Engineering controls : Ensure adequate ventilation. Recirculated air should be filtered to remove respirable dust. Provide for appropriate exhaust ventilation and dust collection at machinery. Static charges can cause explosions in solvent and dust laden atmospheres. Provide grounding of equipment to prevent static build-up. Personal protective equipment Respiratory protection : When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Eye protection Safety glasses with side-shields Exposure Guidelines Exposure Limit Values 4 / 6 Article Information Sheet KEVLAR® Para-aramid Version 2.1 Revision Date: 11/14/2013 Ref. 150000002634 Para-aramid AEL * (Americas 2 RFP/cc 8 & 12 hr. TWA Respirable fibers. only) AEL * (Americas 5 mg/m3 8 & 12 hr. TWA Non-fibrous particulate only) and/or non-respirable fibres. AEL * (Americas 2 RFP/cc 8 & 12 hr. TWA Respirable fibers. only) AEL * (Americas 5 mg/m3 8 & 12 hr. TWA Non-fibrous particulate only) and/or non-respirable fibres. * AEL is DuPont's Acceptable Exposure Limit. Where governmentally imposed occupational exposure limits which are lower than the AEL are in effect, such limits shall take precedence. DISPOSAL CONSIDERATIONS Waste treatment methods Product : Can be landfilled or incinerated, when in compliance with local regulations. Do not flush into surface water or sanitary sewer system. REGULATORY INFORMATION TSCA (US) Status On the inventory, or in compliance with the inventory California Prop. 65: Chemicals known to the State of California to cause cancer, birth defects or other reproductive harm: none requiring notification 5 / 6 Article Information Sheet KEVLAR® Para-aramid Version 2.1 Revision Date: 11/14/2013 Ref. 150000002634
Further information
Restrictions on use Do not use DuPont materials in medical applications involving implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont under a written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use. For further information, please contact your DuPont representative. You may also request a copy of the DuPont POLICY Regarding Medical Applications and DuPont CAUTION Regarding Medical Applications. It is recommended that additional information be requested if an unusual application of synthetic fibres is intended. ® DuPont's registered trademark The information provided in this Article Information Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The above information relates only to the specific material(s) designated herein and may not be valid for such material(s) used in combination with any other materials or in any process or if the material is altered or processed, unless specified in the text. 6 / 6 Disclaimer: The information given by this document is based on the best knowledge at the date shown. It is given in good faith. Furthermore, users attention is drawn to the possible risks run when the product is used for any purpose other than the one for which it was designed. These MSDSs do not exempt users from knowing and applying the rules regulating their activities. Users assume full responsibility for applying the appropriate safety measures when the product is used. The specifications mentioned in these MSDSs are only those of the manufacturers of the raw materials and no further testing was performed by JB Martin. The technical department