Note: Ingredients listed on restricted chemical lists
EC/CAS
259-627-5/55406-53-6
Name of the chemical
3-Iodo-2-propynylbutylcarbamate
Concentration
≤1
General Information
Revision date
2019-11-28
Product name
VALTTI POHJUSTE
1.2.1 Relevant identified uses
Painting work Ready-to-use solventborne colourless wood preservative that penetrates into the substrate for outdoor use (use class 2 and 3) for consumer and professional use
supplier name
Tikkurila Oyj
Emergency telephone
+358 20 191 2000
Icons in SDS
Company Information
company name
Tikkurila Oyj
e-mail address of the competent person responsible for the Safety Data Sheet
productsafety@tikkurila.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H304, H412
Hazard statements
Code
Statements
H304
May be fatal if swallowed and enters airways
Section 2
SECTION 2: Hazards identification
1272/2008]
Product definition
Mixture
Signal word
Danger
Hazard statements
H304 - May be fatal if swallowed and enters airways. H412 - Harmful to aquatic life with long lasting effects.
Precautionary statements
General : P102 - Keep out of reach of children. P101 - If medical advice is needed, have product container or label at hand.
Prevention
P261 - Avoid breathing vapor. P271 - Use only outdoors or in a well-ventilated area. P284 - In case of inadequate ventilation wear respiratory protection: Wear respiratory protection. P273 - Avoid release to the environment.
Response
P301 - IF SWALLOWED: P310 - Immediately call a POISON CENTER or physician. P331 - Do NOT induce vomiting.
Storage
P405 - Store locked up.
Disposal
P501 - Dispose of contents according to the local regulations for hazardous waste and recycle or dispose container in accordance with local regulations.
Contains
3-iodo-2-propynyl butylcarbamate (IPBC). May produce an allergic elements reaction. Repeated exposure may cause skin dryness or cracking. Wear protective gloves. Biocidal products regulation Active substances Name % 3-iodo-2-propynyl butylcarbamate (IPBC) 0.7
Other hazards which do not result in classification
Note! Risk of self-ignition of used cleaning rags, paper wipes etc. Contaminated materials can create fire some hours later and should be soked in water and placed in a closed metal container before disposal.