General Information
Revision date
2020-08-11
Product name
Isoquinoline
CAS No.
119-65-3
Emergency telephone
+64 9 980 6780
Icons in SDS
Company Information
company name
Thermo Fisher Scientific New Zealand Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
NZinfo@thermofisher.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H301, H310, H315, H432
Hazard statements
Code
Statements
H301
Toxic if swallowed
H310
Fatal in contact with skin
H315
Causes skin irritation
Section 2
SECTION 2: Hazards identification
GHS Classification Classification under Work Safe New Zealand 6.1B - Substances that are acutely toxic (Dermal) 6.3A - Substances that are irritating to the skin 6.1C - Substances that are acutely toxic (Oral) 9.3B - Substances that are ecotoxic to terrestrial vertebrates Classified as hazardous according to criteria of EPA New Zealand HSNO Approval Number HSR004527
Physical hazards
Based on available data, the classification criteria are not met
Health hazards
Acute Oral Toxicity Category 3 Acute Dermal Toxicity Category 2 Skin Corrosion/Irritation Category 2
Signal word
Danger
Hazard statements
H310 - Fatal in contact with skin H315 - Causes skin irritation H301 - Toxic if swallowed H432 - Toxic to terrestrial vertebrates
Precautionary statements
P261 - Avoid breathing dust/fume/gas/mist/vapors/spray P262 - Do not get in eyes, on skin, or on clothing P264 - Wash face, hands and any exposed skin thoroughly after handling P270 - Do not eat, drink or smoke when using this product P280 - Wear protective gloves/protective clothing/eye protection/face protection P302 + P352 - IF ON SKIN: Wash with plenty of soap and water P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P310 - Immediately call a POISON CENTER or doctor/physician P330 - Rinse mouth P362 - Take off contaminated clothing and wash before reuse P405 - Store locked up P501 - Dispose of contents/ container to an approved waste disposal plant
Further information
No information available