Note: Ingredients listed on restricted chemical lists
EC/CAS
127-06-0
Name of the chemical
Acetone oxime
Concentration
>95
General Information
Revision date
2023-03-10
Product name
Acetone oxime
Product Synonyms
Acetoxime
CAS No.
127-06-0
Emergency telephone
+64 9 980 6780
Icons in SDS
Company Information
company name
Thermo Fisher Scientific New Zealand Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
ANZinfo@thermofisher.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H228, H318, H373
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
H228
Flammable solid
H318
Causes serious eye damage.
H373
May cause damage to organs through prolonged or repeated exposure
Section 2
SECTION 2: Hazards identification
GHS Classification Classification under Work Safe New Zealand Classified as hazardous in accordance with the criteria of EPA New Zealand
Physical hazards
Flammable solids Category 1 Category 3
Health hazards
Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity - (repeated exposure) Category 2
Environmental hazards
Based on available data, the classification criteria are not met
Signal word
Danger
Hazard statements
H228 - Flammable solid H318 - Causes serious eye damage H373 - May cause damage to organs through prolonged or repeated exposure H226 - Flammable liquid and vapor
Prevention
P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking P240 - Ground and bond container and receiving equipment P280 - Wear protective gloves/protective clothing/eye protection/face protection
Response
P310 - Immediately call a POISON CENTER or doctor P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P370 + P378 - In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish
Storage
P403 - Store in a well-ventilated place
Disposal
P501 - Dispose of contents/ container to an approved waste disposal plant