Note: Ingredients listed on restricted chemical lists
EC/CAS
75-28-5
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
99.5-100
General Information
Version
3
Revision date
2023-07-14
Product name
Isobutane Refrigerant Gas
Product Synonyms
2-methylpropane, trimethylmethane, refrigerant gas R600a
CAS No.
75-28-5
1.2.2. Uses advised against
This product does not contain any substance(s) on the Illicit Drug Precursors/Reagents list This product does not contain any substance(s) subject to Prohibition, Authorization or Restriction. This product does not contain any substance(s) listed on the voluntary National Code of Practice for Chemicals of Security Concern
Emergency telephone
+613 9757 4559
Icons in SDS
Company Information
company name
ThermoFisher Scientific Australia Pty Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
ANZinfo@thermofisher.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
SECTION 2: Hazards identification
Classified as hazardous according to criteria of Safe Work Australia. Classification under Safe Work Australia
Physical hazards
Flammable gases Gases under pressure
Environmental hazards
No hazards identified
Signal word
Danger
Hazard statements
H220 - Extremely flammable gas H280 - Contains gas under pressure; may explode if heated AUH018 - In use, may form flammable/explosive vapor-air mixture
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking P271 - Use only outdoors or in a well-ventilated area P304 + P312 - IF INHALED: Call a POISON CENTER or doctor if you feel unwell P304 + P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing P302 - IF ON SKIN P336 - Thaw frosted parts with lukewarm water. Do no rub affected area P313 - Get medical advice/attention P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely P381 - In case of leakage, eliminate all ignition sources
Further information
Contact with product may cause frostbite This product does not contain any known or suspected endocrine disruptors
2.1 Classification of the substance or mixture
Classified as hazardous according to criteria of Safe Work Australia Physical hazards Flammable gases Gases under pressure Health hazards Environmental hazards No hazards identified