Note: Ingredients listed on restricted chemical lists
EC/CAS
75-12-7
Name of the chemical
Formamide
Concentration
>=95-<97.5
General Information
Revision date
2026-09-06
Product name
Gel Loading Buffer II
Product Synonyms
None
1.2.1 Relevant identified uses
For research use only. Not for use in diagnostic procedures
1.2.2. Uses advised against
Consumer use
Emergency telephone
1-800-424-9300, 1-703-527-3887, 1-703-741-5970
Icons in SDS
Company Information
company name
Thermo Fisher Scientific Baltics UAB
e-mail address of the competent person responsible for the Safety Data Sheet
MSDS@lifetech.com
Hazard Codes
Hazard statements (CLP)
H351, H360, H373
Hazard statements
Code
Statements
H351
Suspected of causing cancer
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture Carcinogenicity Category 2 Reproductive toxicity Category 1B Specific target organ toxicity (repeated exposure) Category 2 Hazards not otherwise classified (HNOC) Not applicable Label elements Danger Hazard statements Suspected of causing cancer May damage fertility or the unborn child May cause damage to organs through prolonged or repeated exposure Precautionary Statements - Prevention Obtain special instructions before use Do not handle until all safety precautions have been read and understood Do not breathe dust Wear protective gloves, protective clothing, eye protection, face protection, and hearing protection Precautionary Statements - Response IF exposed or concerned: Get medical advice/attention Precautionary Statements - Storage Store locked up
Precautionary statements
Disposal Dispose of contents and container in accordance with local, regional, national, and international regulations as applicable.
Further information
No information available.
2.1 Classification of the substance or mixture
Carcinogenicity Category 2 Reproductive toxicity Category 1B Specific target organ toxicity (repeated exposure) Category 2 Hazards not otherwise classified (HNOC) Not applicable.