General Information
Revision date
2016-01-14
Product name
Extraction Buffer
REACH No
is
1.2.2. Uses advised against
Not for consumer use
Emergency telephone
(Spill, Leak, Fire, Exposure or Accident), call
Icons in SDS
Company Information
company name
Thermo Fisher Scientific Baltics UAB
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H302, H315, H319, H335, H412
Hazard statements
Code
Statements
H302
Harmful if swallowed
Section 2
Physical hazards
Not Hazardous
Health hazards
Acute oral toxicity Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2 Specific target organ toxicity - Single exposure Category 3
Environmental hazards
Chronic aquatic toxicity Category 3
Additional information
No information available
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008 [CLP]
Signal word
Warning
Hazard statements
H315 - Causes skin irritation H319 - Causes serious eye irritation H302 - Harmful if swallowed H335 - May cause respiratory irritation H412 - Harmful to aquatic life with long lasting effects
Prevention
P264 - Wash hands thoroughly after handling P280 - Wear protective gloves/protective clothing/eye protection/face protection P261 - Avoid breathing dust/fume/gas/mist/vapours/spray P273 - Avoid release to the environment P270 - Do not eat, drink or smoke when using this product
Response
P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTRE or doctor/physician P302 + P352 - IF ON SKIN: Wash with plenty of soap and water P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P304 + P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing P330 - Rinse mouth
Storage
P403 + P233 - Store in a well-ventilated place. Keep container tightly closed
Disposal
P501 - Dispose of contents/ container to an approved waste disposal plant
2.3 Other hazards
This mixture does not contain any substances that are assessed to be a PBT or a vPvB