Cerafiber Wet Pack, Ceraform 102, Ceraform 103, Ceraform 140, Ceraform 141, Cerwool Wet Wrap HT, Kaowool 12C Boards and Shapes, Kaowool 2300H Boards and Shapes,Kaowool 2300R Boards and Shapes, Kaowool A, Kaowool HP Board, Kaowool M Board, Kaowool PM Board, Kaowool Rigidized M, Kaowool Riser, Kaowool Wet, Pyro-Bloc Plus IT, Pyro-BlocPlus XT, Thermotect A, Thermotect AR, Thermotect HP, Thermotect HT, Thermotect LD, The above mentioned product contains Refractory Ceramic Fibre (RCF) (Aluminosilicate glass w...

THERMAL CERAMICS LIMITED

Revision date : 2024-04-01

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS08
Health risk rating 5
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

142844-00-6

Name of the chemical

Zirconia Aluminosilicate Refractory Ceramic Fibres

Concentration

70- 2119458050-50 01-

EC/CAS

7631-86-9

Name of the chemical

Silver adsorbed on silicon dioxide

Concentration

5-15 2119379499-16

EC/CAS

9005-25-8

Name of the chemical

Starch

Concentration

2-10

General Information

Revision date

2024-04-01

Product name

Cerafiber Wet Pack, Ceraform 102, Ceraform 103, Ceraform 140, Ceraform 141, Cerwool Wet Wrap HT, Kaowool 12C Boards and Shapes, Kaowool 2300H Boards and Shapes,Kaowool 2300R Boards and Shapes, Kaowool A, Kaowool HP Board, Kaowool M Board, Kaowool PM Board, Kaowool Rigidized M, Kaowool Riser, Kaowool Wet, Pyro-Bloc Plus IT, Pyro-BlocPlus XT, Thermotect A, Thermotect AR, Thermotect HP, Thermotect HT, Thermotect LD, The above mentioned product contains Refractory Ceramic Fibre (RCF) (Aluminosilicate glass w...

Chemical name

Refractories, fibres, aluminosilicate

CAS No.

142844-00-6

REACH No

01-2119458050-50-0002

1.2.1 Relevant identified uses

is restricted to professional users for application as thermal insulation, heat shields, heat containment, gaskets and expansion joints at temperatures up to 1400°C in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace and automotive industries. Products are not intended for direct sale to the general public • Primary Use: Manufacture of fibre (this use refers to the initial production of the fibre and is therefore not relevant to the downstream user) • Secondary ...

1.2.2. Uses advised against

Spraying of the product

Emergency telephone

44 (0) 7931 963 973

Icons in SDS

GHS08

Company Information

company name

THERMAL CERAMICS LIMITED

e-mail address of the competent person responsible for the Safety Data Sheet

sds.tc@morganplc.com

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H350I, H350i

Hazard statements

Code

Statements

H350i

May cause cancer by inhalation.

Section 2

SECTION 2: Hazards identification

(EC) No. 1272/2008 Classification of the substance/ mixture

2.2 Label elements

Component

Hazard statements

Refractory Ceramic Fibres (Alumino-silicate wools) May cause cancer by inhalation (H350i)

Hazard pictograms

GHS 08

Signal word

Danger

Precautionary statements

not handle until all safety instructions have been read and understood. (P202) Use personal protective equipment as required. (P281)

Other hazards which do not result in classification

CHRONIC EFFECTS FOR CRYSTALLINE SILICA These products may contain minimal amounts of crystalline silica. Prolonged/repeated inhalation of respirable crystalline silica dust may cause delayed lung injury (silicosis). IARC (International Agency for Research on Cancer) states that there is "sufficient evidence in humans for the carcinogenicity of inhaled crystalline silica in the form of quartz or cristobalite from occupational sources to classify crystalline silica as carcinogenic to humans (Group 1)". (Monograph V 68) In making the overall evaluation the Working Group noted however that carcinogenicity in humans was not detected in all industrial circumstances studied.

2.1 Classification of the substance or mixture

2.1.1 Classification according to Regulation (EC) No 1272/2008 Under the Classification, Labelling and Packaging regulations (CLP) 1272/2008 EEC RCF/ASW has been classified as a 1B carcinogen. 2.1.2 Additional information: The International Agency for Research on Cancer (IARC) reaffirmed in 2001 that group 2B ("possibly carcinogenic to humans") remains the appropriate classification for RCF/ASW. In accordance with 1st adaptation to Technical Progress of Regulation (EC) No 1272/2008 as published 10th August 2009, the classification as "irritant" has been removed for all types of manmade vitreous fibres (MMVFs).

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.