Note: Ingredients listed on restricted chemical lists
EC/CAS
9004-62-0
Name of the chemical
hydroxyethylcellulose
Concentration
N/A
General Information
Revision date
2019-11-11
Product name
Ferroweld
1.2.1 Relevant identified uses
SMAW (Shielded Metal Arc Welding)
1.2.2. Uses advised against
Not known. Read this SDS before using this product
Emergency telephone
USA/Canada/Mexico
Icons in SDS
Company Information
company name
The Lincoln Electric Company
GHS Information
Signal word
Warning
Section 2
2.1 Classification of the substance or mixture
Not classified as hazardous according to applicable GHS hazard classification criteria.
Hazard pictograms
No symbol
Signal word
No signal word.
Hazard statements
Not applicable
Precautionary statements
Not applicable Other hazards which do not None. result in GHS classification: Substance(s) formed under the The welding fume produced from this welding electrode may contain the conditions of use: following constituent(s) and/or their complex metallic oxides as well as solid particles or other constituents from the consumables, base metal, or base metal coating not listed below. Chemical Identity CAS-No. Carbon dioxide 124-38-9 Carbon monoxide 630-08-0 Nitrogen dioxide 10102-44-0 Ozone 10028-15-6 Manganese 7439-96-5 Fluorides (as F) 16984-48-8