General Information

Revision date

2003-12-16

Product name

HARRIS AMERICAN LFB / FC (formerly Welco 15 and Welco 15FC)

Product Synonyms

Not Applicable

1.2.1 Relevant identified uses

Metal Brazing

Emergency telephone

1-800-424-9300

Icons in SDS

M004 M008 M009 M010 M013 M017

Company Information

company name

HARRIS PRODUCTS GROUP

e-mail address of the competent person responsible for the Safety Data Sheet

salesinfo@jwharris.com

Section 2

RISK CLASSIFICATION

C Carcinogen: EPA-D Iron 7439-89-6 1.0 5, A4 (Not NE 10 NE 2500 NIOSH REL: (exposure limits are for Classifiable TWA = 5 iron oxide dust and fume as a Human DFG MAK: [Fe2O3], as Fe) Carcinogen) TWA = 6 (Respirable Fraction) Carcinogen: IARC-3, TLV-A4 Silicon 7440-21-3 0.50 10 NE 15 (Total NE NIOSH REL: dust) TWA = 10 (Total dust; 5 5 (Respirable (Respirable fraction) fraction) 10 (Total dust) (vacated 1989 PEL) COMPONENT 2: FLUX COATING ON RODS Boric Acid 10043-35-3 50-80 NE Methacrylate/Aliphatic & Proprietary NE Naphthenic Hydrocarbon Compound Borax Glass 1303-96-4 10-30 NE 10 (Vacated NE NIOSH REL: (the exposure limits are 1989 PEL) TWA = 1 for Borates, anhydrous) NE = Not Established. See Section 16 for Definitions of Terms Used. NOTE (1): The ACGIH has an established exposure limit for Welding Fumes, Not Otherwise Classified. The Threshold Limit Value is 5 mg/m 3. NIOSH classifies welding fumes as carcinogens. Single values shown are maximum, unless otherwise noted. NOTE (2): ALL WHMIS required information is included in appropriate sections based on the ANSI Z400.1-1998 format. This product has been classified in accordance with the hazard criteria of the CPR and the MSDS contains all the information required by the CPR.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.