General Information
Version
6.4
Revision date
2023-03-24
Product name
Opteon SF80 Specialty Fluid
1.2.2. Uses advised against
For use in industrial installations only., Do not use product for anything outside of the above specified uses
supplier name
The Chemours Company FC, LLC
Emergency telephone
1-302-773-1000, 1-866-595-1473, +1-800-424-9300, +1-703-527-3887, 1-302- 773-2000
Icons in SDS
Company Information
company name
The Chemours Company FC, LLC
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H320, H336
Hazard statements
Code
Statements
H320
Causes eye irritation
H336
May cause drowsiness or dizziness
Section 2
SECTION 2: Hazards identification
OSHA Hazards GHS classification in accordance with the
2.1 Classification of the substance or mixture
in accordance with the
Signal word
Warning
Hazard statements
H320 Causes eye irritation. H336 May cause drowsiness or dizziness.
Prevention
P261 Avoid breathing mist or vapors. P264 Wash skin thoroughly after handling. P271 Use only outdoors or in a well-ventilated area.
Response
P304 + P340 + P312 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a doctor if you feel unwell. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 If eye irritation persists: Get medical attention.
Storage
P405 Store locked up.
Disposal
P501 Dispose of contents and container to an approved waste disposal plant.
2.3 Other hazards
In use, may form flammable/explosive vapor-air mixture. Vapors are heavier than air and can cause suffocation by reducing oxygen available for breathing. Misuse or intentional inhalation abuse may cause death without warning symptoms, due to cardi- ac effects. Rapid evaporation of the product may cause frostbite.