Note: Ingredients listed on restricted chemical lists
EC/CAS
206-557-8/354-33-6
Name of the chemical
Ethane, pentafluoro
Concentration
25,00-<
EC/CAS
212-377-0/811-97-2
Name of the chemical
1,1,1,2-Tetrafluoroethane
Concentration
10,00-<
EC/CAS
468-710-7/754-12-1
Name of the chemical
2,3,3,3-Tetrafluoropropene
Concentration
10,00-<
EC/CAS
471-480-0/1645-83-6
Name of the chemical
Trans-1,3,3,3-tetrafluoropropene
Concentration
5,00-<
General Information
Version
2.1.0, issued
Revision date
2025-08-04
Product name
R-448A
Emergency telephone
+49 (0)551 192 40
Icons in SDS
Company Information
company name
TEGA - Technische Gase und Gasetechnik GmbH
e-mail address of the competent person responsible for the Safety Data Sheet
kaeltemittel@tega.de
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H280
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
Regulation (EC) No. 1272/2008 Classification of the substance or mixture
Hazard pictograms
GHS04
Signal word
Warning
Hazard statements
H280 Contains gas under pressure; may explode if heated. GER
Precautionary statements
P410+P403 Protect from sunlight. Store in a well-ventilated place.
Supplemental label elements
Contains fluorinated greenhouse gases.
2.3 Other hazards
High vapour concentrations can cause headaches, dizziness, drowsiness, nausea and even unconsciousness. May cause arrhythmia. PBT assessment The product is not considered to be a PBT. vPvB assessment The product is not considered to be a vPvB.
2.1 Classification of the substance or mixture
Classification in accordance with Regulation (EC) No 1272/2008 (CLP) Press. Gas liq.; H280 Classification information This product is assessed and classified using the methods and criteria below referred to in Article 9 of Regulation (EC) n° 1272/2008: Physical hazards: determined through assessment data based on the methods or standards referred to in part 2 of Annex I to CLP Health hazards and environmental hazards: determined through toxicological and ecotoxicological assessment data based on the methods or standards referred to in Part 3, 4 and 5 of Annex I to CLP.