Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-44-0
Name of the chemical
Carbon black
Concentration
>=30-<60
General Information
Version
1.0
Revision date
2024-11-21
Product name
Rhodium 5% on Carbon (wetted with ca. 55% Water)
1.2.1 Relevant identified uses
Use as laboratory reagent
supplier name
TCI America
Emergency telephone
+1-800-4238616, +1-503-2831681, +1-888-5201075, +1-503-2831987, +1-503-2867624, +1-800-4249300, +1-703-5273887
Icons in SDS
Company Information
company name
TCI America
e-mail address of the competent person responsible for the Safety Data Sheet
sales-US@TCIchemicals.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H250, H334
Hazard statements
Code
Statements
H250
Catches fire spontaneously if exposed to air
H334
May cause allergy or asthma symptoms or breathing difficulties if inhaled
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
in accordance with the Hazardous Products Regulations Pyrophoric solids Category 1 Respiratory sensitisation Category 1
Signal word
Danger
Hazard statements
H250 Catches fire spontaneously if exposed to air. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.
Prevention
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P222 Do not allow contact with air. P231 + P232 Handle and store contents under inert gas. Protect from moisture. P233 Keep container tightly closed. P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection. P284 Wear respiratory protection.
Response
P302 + P335 + P334 IF ON SKIN: Brush off loose particles from skin. Immerse in cool water or wrap in wet bandages. P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P342 + P311 If experiencing respiratory symptoms: Call a POISON CENTER/ doctor. P370 + P378 In case of fire: Use dry sand, dry chemical or alcohol- resistant foam to extinguish.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
Other hazards
None known