Note: Ingredients listed on restricted chemical lists
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
80-98 4-44 1-5
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
<3
EC/CAS
1314-13-2
Name of the chemical
Zinc oxide; C.I. 77947
Concentration
<2
EC/CAS
1333-86-4
Name of the chemical
carbon black
Concentration
<1 <1
EC/CAS
10217-34-2
Name of the chemical
2-(3,4-epoxycyclohexyl)ethyltriethoxy silane
Concentration
<0.1
EC/CAS
64742-52-5
Name of the chemical
Distillates (petroleum), hydrotreated heavy naphthenic
Concentration
N/A
EC/CAS
64742-65-0
Name of the chemical
Distillates (petroleum), solvent-dewaxed heavy paraffinic
Concentration
N/A
General Information
Revision date
2022-02-08
Product name
Roofing Granules
Chemical name
Mixture
1.2.1 Relevant identified uses
Roofing Manufacturing
Emergency telephone
1-417-624-6644, 1-800-424-9300
Icons in SDS
Company Information
company name
TAMKO Building Products LLC
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
Signal word
Danger
2.1 Classification of the substance or mixture
Carcinogenicity – Category 1A Specific Target Organ Toxicity, Repeated Exposure – Category 2 (lungs)
Hazard statements
May cause cancer. May cause damage to organs (lungs) through prolonged or repeated exposure.
Additional information
Can cause silicosis and other permanent lung damage
Prevention
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe dust. Wear protective gloves/protective clothing/eye protection/face protection.
Response
In case of fire: See Section 5. Specific treatment: See section 4-First Aid Get medical advice/attention: If exposed or concerned or you feel unwell; and/or if respiratory irritation persists.
Storage
Store locked up.
Disposal
Dispose in accordance with Federal, State, and Local regulations. (See section 13 for additional information).