Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-44-0
Name of the chemical
Carbon black
Concentration
N/A
EC/CAS
1313-99-1
Name of the chemical
Nickel monoxide
Concentration
N/A
EC/CAS
1307-96-6
Name of the chemical
Cobaltoxid (in Form atembarer Stäube/Aerosole)
Concentration
<20%
General Information
Revision date
2018-11-02
Product name
Stihl HSA 25 Battery Pack
1.2.1 Relevant identified uses
Rechargeable Lithium ion battery for electric power tools
1.2.2. Uses advised against
Use only with Stihl cordless power tools
supplier name
Stihl Pty Ltd
Emergency telephone
(Aust 131 126; NZ 0800 764 766
Icons in SDS
Company Information
company name
Stihl Pty Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
csc@stihl.com.au, info@stihl.co.nz
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H301, H314, H317, H334, H350i, H360f, H372, H410
Hazard statements
Code
Statements
H301
Toxic if swallowed
Section 2
Classification according to GHS
CLASS & CATEGORY: The product is a Lithium ion battery and is therefore classified as an article and is not hazardous when used according to the recommendations of the manufacturer. The hazard is associated with the contents of the battery. Under recommended use conditions, the electrode materials and liquid electrolyte are non-reactive provided that the battery integrity remains, and the seals remain intact. The potential for exposure should not exist unless the battery leaks, is exposed to high temperatures or is mechanically, electrically or physically abused/damaged. If the battery is compromised and starts to leak, based upon the battery ingredients, under the Model Work Health and Safety Regulations, the ingredients in the product would be rated as hazardous as per Section 2.3 Other Hazards* CLASS & CATEGORY: Under the Model Work Health and Safety Regulations the product would be rated by calculation as Hazardous: Acute Toxicity - Oral - Category 3 Skin Corrosion/Irritation - Category 1B Sensitisation - Skin - Category 1 Sensitisation - Respiratory - Category 1 Carcinogenicity - Category 1A Toxic to Reproduction - Category 1B Specific Target Organ Toxicity (Repeated Exposure) - Category 1 Chronic Aquatic Toxicity - Category 1
2.2 Label elements
No Work Health and Safety labelling is applicable to the battery which is considered an Article. If the battery is compromised and starts to leak, based upon the battery ingredients, under the Model Work Health and Safety Regulations, the ingredients in the product would be rated as hazardous and the Label Elements and Precautionary Statements as per Section 2.3 Other Hazards* will be applicable.
Signal word
Not Applicable. Danger.
Hazard pictograms
Not Applicable.
Hazard statements
Not Applicable. H301 - Toxic if swallowed. H314 - Causes severe skin burns and eye damage. H317 - May cause an allergic skin reaction. H334 - May cause allergy or asthma symptoms or breathing difficulties if inhaled. H350i - May cause cancer by inhalation. H360f - May damage fertility. H372 - Causes damage to organs through prolonged or repeated exposure if swallowed or inhaled. H410 - Very toxic to aquatic life with long lasting effects.
Prevention
Not Applicable. P102 - Keep out of reach of children. P202 - Do not handle until all safety precautions have been read and understood. P260 - Do not breathe fume/mist/vapours. P264 - Wash hands thoroughly after handling. P270 - Do not eat, drink or smoke when using this product. P272 - Contaminated work clothing should not be allowed out of the workplace. P273 - Avoid release to the environment. P280 - Wear protective gloves/protective clothing/eye protection/face protection. P285 - In case of inadequate ventilation wear respiratory protection.
Response
Not Applicable. P301+P330+P331 - IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P303+P361+P353 - IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. P304+P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P308 + P313 - IF exposed or concerned: Get medical advice/attention. P310 - Immediately call a POISON CENTRE or doctor/physician. P333 + P313 - If skin irritation or rash occurs: Get medical advice/attention. P342 + P311 - If experiencing respiratory symptoms: Call a POISON CENTRE or doctor/physician. P363 - Wash contaminated clothing before reuse. P390 - Absorb spillage/leaking electrolyte to prevent material damage. P391 - Collect spillage. Continued
Storage
Not Applicable. P405 - Store locked up. P406 - Store any spilled/leaking electrolyte material in a corrosive resistant container with a resistant inner liner.
Disposal
Not Applicable. Continued P501 - Dispose of contents/container in accordance with local regulations. ADDITIONAL HAZARDS: Lithium-Ion Batteries have a gas tight seal and are safe as long as they are handled in accordance with the manufacturer’s specifications. When re- charging batteries, always use chargers which are suitable for the battery type. Do not short-circuit batteries. Do not cause mechanical damage to batteries, by processes such as puncturing, deforming, disassembling, etc. Do not heat them above the permitted temperature (120oC) or burn them. Keep batteries away from small children. Never assume a battery is fully discharged. Batteries can contain a considerable amount of energy, which may be a source of high electric current and lead to severe electrical shock in the event of a short-circuit.
2.3 Other hazards
The following hazards are associated with the battery if the unit is compromised and the materials escape. They represent the hazards of the contents of the product that are not available under normal conditions of use but may create exposure if the casing of the article is damaged or breached.