Note: Ingredients listed on restricted chemical lists
EC/CAS
80-62-6
Name of the chemical
methacrylic acid, methyl ester
Concentration
N/A
EC/CAS
97-90-5
Name of the chemical
methacrylic acid, diester with ethyleneglycol
Concentration
N/A
General Information
Revision date
2016-05-31
Product name
Excel Formula Heat-Cure Denture Base Material (Liquid)
CAS No.
80-62-6
REACH No
01-2119452498-28
1.2.1 Relevant identified uses
Dental / Denture application
Emergency telephone
1-352-323-3500 (International
Icons in SDS
Company Information
company name
St. George Technology, Inc
GHS Information
Signal word
Danger
Section 2
2.1 Classification of the substance or mixture
Skin Corrosion/Irritation Category 2 Serious Eye Damage/Eye Irritation Category 2 Skin sensitization Category 1 Specific target organ toxicity (single exposure) Category 3 Flammable liquids Category 2
Signal word
Danger
Hazard statements
Causes skin irritation Causes severe eye irritation May cause an allergic skin reaction May cause respiratory irritation. May cause drowsiness or dizziness Highly flammable liquid and vapor Appearance Colorless liquid Physical State Liquid Odor Characteristic
Prevention
Wash face, hands and any exposed skin thoroughly after handling Wear protective gloves/protective clothing/eye protection/face protection Avoid breathing dust/fume/gas/mist/vapors/spray Contaminated work clothing should not be allowed out of the workplace Use only outdoors or in a well-ventilated area Keep away from heat/sparks/open flames/hot surfaces. — No smoking Keep container tightly closed Ground/bond container and receiving equipment Use explosion-proof equipment Use only non-sparking tools Take precautionary measures against static discharge Keep cool
Response
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing Get medical attention if irritation occurs If skin irritation or rash occurs: Get medical advice/attention IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower Wash contaminated clothing before reuse IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing Call a POISON CENTER or doctor/physician if you feel unwell In case of fire: Use CO2, dry chemical, or foam for extinction
Storage
Store in a well-ventilated place. Keep container tightly closed Store locked up
Precautionary statements
Disposal Dispose of contents/container to an approved waste disposal plant
2.3 Other hazards
Harmful to aquatic life with long lasting effects Harmful to aquatic life