Note: Ingredients listed on restricted chemical lists
EC/CAS
13674-84-5
Name of the chemical
Tris(2-chloro-1-methylethyl) phosphate
Concentration
N/A
General Information
Revision date
2017-07-18
Product name
Paratherm G
Chemical name
Polyisocyanurate (insulation)
supplier name
Siplast
Emergency telephone
800-424-9300
Icons in SDS
Company Information
company name
Siplast
Section 2
SECTION 2: Hazards identification
OSHA As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed below are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. ADDITIONAL HAZARD IDENTIFICATION INFORMATION:
Principle Routes of Exposure
Inhalation SIGNS & SYMPTOMS OF EXPOSURE EYES: May cause irritation to the eyes. SKIN: May cause irritation to the skin. This product is not intended to be ingested. If ingested, it may INGESTION: cause temporary irritation to the gastrointestinal (digestive) tract. INHALATION: May cause irritation to the respiratory tract. Inhalation of high vapor concentrations of pentanes used in this product may cause dizziness, headaches, anesthesia, drowsiness, unconsciousness, and other central nervous system effects, including death.
Medical Conditions Generally Aggravated by Exposure
The dust produced by reprocessing of this product may aggravate pre- existing respiratory diseases.
Health hazards
This product contains tris(monochloropropyl) phosphate which may cause skin sensitization. CARCINOGENICITY: Direct implantation of glass fibers into the lung tissue of laboratory animals has produced lung fibrosis and lung cancer. Human epidemiological studies of inhalation exposure have yielded negative results. NTP Listed; Carcinogen IARC Class 3.