General Information
Version
8.7
Revision date
2024-10-11
Product name
Hydroiodic acid 57% for analysis EMSURE
CAS No.
10034-85-2
1.2.1 Relevant identified uses
Reagent for analysis 1.4
Emergency telephone
+65 6890 6633, +65 6890 6639, +65 3158 1349
Icons in SDS
Company Information
company name
Sigma-Aldrich Pte Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
TechnicalService@merckgroup.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H290, H314, H411
Hazard statements
Code
Statements
H290
May be corrosive to metals
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Corrosive to Metals : Category 1 Skin corrosion/irritation : Category 1 Serious eye damage/eye : Category 1 irritation
Long term hazards
Category 2 aquatic hazard
Signal word
Danger
Hazard statements
H290 May be corrosive to metals. H314 Causes severe skin burns and eye damage. H411 Toxic to aquatic life with long lasting effects.
Prevention
P264 Wash skin thoroughly after handling. P273 Avoid release to the environment. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water. P304 + P340 + P310 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immedi- ately call a POISON CENTER/ doctor. P305 + P351 + P338 + P310 IF IN EYES: Rinse cau- tiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/ doctor. P390 Absorb spillage to prevent material damage. P391 Collect spillage.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
Other hazards which do not result in classification
None known.