General Information
Version
8.4
Revision date
2023-08-02
Product name
SMC Phospho-Tau (T181) High Sensitivity Immunoassay Kit
1.2.1 Relevant identified uses
Biochemical research/analysis, Use restricted under TSCA to research and development or as analytical reagent. Uses regulated under FDA or FIFRA are not affected
Emergency telephone
+64 9 801 0034
Icons in SDS
Company Information
company name
SIGMA-ALDRICH NEW ZEALAND CO
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H302, H302+H332, H311, H319, H332, H360, H373, H412
Hazard statements
Code
Statements
H302
Harmful if swallowed
H302+H332
Harmful if swallowed or if inhaled
H311
Toxic in contact with skin
H319
Causes serious eye irritation
H332
Harmful if inhaled
H360
May damage fertility or the unborn child
H373
May cause damage to organs through prolonged or repeated exposure
H412
Harmful to aquatic life with long lasting effects
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Acute toxicity, Oral (Category 4), H302 Acute toxicity, Inhalation (Category 4), H332 Acute toxicity, Dermal (Category 3), H311 Serious eye damage/eye irritation (Category 2), H319 Reproductive toxicity (Category 1), H360 Specific target organ toxicity - repeated exposure, Oral (Category 2), Brain, H373 Specific target organ toxicity - repeated exposure, Inhalation (Category 2), Respiratory Tract, H373 Hazardous to the aquatic environment - chronic hazard (Category 3), H412 For the full text of the H-Statements mentioned in this Section, see Section 16.
Signal word
Danger
Hazard statements
H302 + H332 Harmful if swallowed or if inhaled. H311 Toxic in contact with skin. H319 Causes serious eye irritation. H360 May damage fertility or the unborn child. H373 May cause damage to organs (Brain) through prolonged or repeated exposure if swallowed. H373 May cause damage to organs (Respiratory Tract) through prolonged or repeated exposure if inhaled. H412 Harmful to aquatic life with long lasting effects.
Prevention
P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P260 Do not breathe mist or vapors. P264 Wash skin thoroughly after handling. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
P308 + P313 IF exposed or concerned: Get medical advice/ attention.
Storage
P405 Store locked up.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
Other hazards
- none