Lipopolysaccharides, from Escherichia coli

Sigma-Aldrich Inc

Revision date : 2021-06-11

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS06
Health risk rating 5
Safety risk rating 1
Environmental risk rating 1

General Information

Version

6.2

Revision date

2021-06-11

Product name

Lipopolysaccharides, from Escherichia coli

CAS No.

93572-42-0

Emergency telephone

800-424-9300 CHEMTREC (USA) +1-703- 527-3887 CHEMTREC (International) 24

Icons in SDS

GHS06

Company Information

company name

Sigma-Aldrich Inc

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H300

Hazard statements

Code

Statements

H300

Fatal if swallowed

Section 2

SECTION 2: Hazards identification

Signal word

Danger

Hazard statements

H300 Fatal if swallowed. SECTION 5: Firefighting measures 5.1 Extinguishing media Suitable extinguishing media Water Foam Carbon dioxide (CO2) Dry powder Unsuitable extinguishing media For this substance/mixture no limitations of extinguishing agents are given. 5.2 Special hazards arising from the substance or mixture Nature of decomposition products not known. Combustible. Development of hazardous combustion gases or vapours possible in the event of fire. 5.3 Advice for firefighters Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing. 5.4

Further information

Prevent fire extinguishing water from contaminating surface water or the ground water system. SECTION 6: Accidental release measures 6.1 Personal precautions, protective equipment and emergency procedures Advice for non-emergency personnel: Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8. 6.2 Environmental precautions Do not let product enter drains. 6.3 Methods and materials for containment and cleaning up Clean up and decontaminate all materials for disposal, as well as contaminated surfaces, with an effective decontamination method such as autoclaving, incineration, or chemical disinfection.Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully. Dispose of properly. Clean up affected area. Avoid generation of dusts. 6.4 Reference to other sections For disposal see section 13. SECTION 7: Handling and storage 7.1 Precautions for safe handling For precautions see section 2.2. 7.2 Conditions for safe storage, including any incompatibilities Storage conditions Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons. Storage stability Recommended storage temperature 2 - 8 °C Keep in a dry place. Storage class (TRGS 510) 6.1A Combustible, acute toxic Cat. 1 and 2 / very toxic hazardous materials 7.3 Specific end use(s) Apart from the uses mentioned in section 1.2 no other specific uses are stipulated SECTION 8: Exposure controls/personal protection 8.1 Control parameters Ingredients with workplace control parameters Contains no substances with occupational exposure limit values. 8.2 Exposure controls Appropriate engineering controls Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance. Personal protective equipment Eye/face protection Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses Skin protection This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Full contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Material tested:KCL 741 Dermatril® L This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Splash contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Material tested:KCL 741 Dermatril® L Body Protection protective clothing Respiratory protection required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Control of environmental exposure Do not let product enter drains. SECTION 9: Physical and chemical properties 9.1 Information on basic physical and chemical properties

Appearance/Odor

Form: powder, (lyophilized) No data available c) Odor Threshold No data available d) pH No data available e) Melting No data available point/freezing point f) Initial boiling point No data available and boiling range g) Flash point ()No data available h) Evaporation rate No data available i) Flammability (solid, No data available gas) j) Upper/lower No data available flammability or explosive limits k) Vapor pressure No data available l) Vapor density No data available m) Relative density No data available n) Water solubility soluble o) Partition coefficient: No data available n-octanol/water p) Autoignition No data available temperature q) Decomposition No data available temperature r) Viscosity No data available s) Explosive properties No data available t) Oxidizing properties No data available

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs