Note: Ingredients listed on restricted chemical lists
General Information
Revision date
2013-01-23
Product name
IMMULITE 2000 Troponin I
CAS No.
26628-22-8
1.2.1 Relevant identified uses
Diagnostic Agents
Emergency telephone
+49 6131 - 19240; [24x7x365
Icons in SDS
Company Information
company name
Siemens Healthcare Diagnostics Limited
e-mail address of the competent person responsible for the Safety Data Sheet
dx.msds.healthcare@siemens.com
Section 2
SECTION 2: Hazards identification
Directive 1999/45/EC: The product is classified as dangerous according to Directive 1999/45/EC and its amendments.
2.1 Classification of the substance or mixture
Xn; R22 R52/53
Other physicochemical hazards
Troponin I Reagent Wedge Not applicable. Troponin I Adjustors Not applicable.
Health hazards
Troponin I Reagent Wedge Not applicable. Troponin I Adjustors Harmful if swallowed.
Environmental hazards
Troponin I Reagent Wedge Not applicable. Troponin I Adjustors Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment. See section 11 for more detailed information on health effects and symptoms.