GHS09 GHS07
Health risk rating 4
Safety risk rating 1
Environmental risk rating 4

Note: Ingredients listed on restricted chemical lists

EC/CAS

247-500-7/55965-84-9

Name of the chemical

Mixture of 5-chloro-2-methyl-2H- isothiazol-3-one (EINECS 247-500-7) and 2-methyl-2H-isothiazol-3-one (EINECS 220-239-6)

Concentration

<0.06

EC/CAS

220-239-6/26628-22-8

Name of the chemical

Sodium Azide

Concentration

<0.1

General Information

Revision date

2024-01-09

Product name

Atellica CH Revised C-Reactive Protein Calibrator (RCRP CAL)

1.2.1 Relevant identified uses

RCRP Calibrator Level 1 Diagnostic agents RCRP Calibrator Levels 2-5 Diagnostic agents

supplier name

Siemens Healthcare Diagnostics Limited

Emergency telephone

+44 20 3807 3798

Icons in SDS

GHS07 GHS09 M004 M009 M010 M011 M017

Company Information

company name

Siemens Healthcare Diagnostics Limited

e-mail address of the competent person responsible for the Safety Data Sheet

dx.msds.healthcare@siemens-healthineers.com

GHS Information

Signal word

RCRP Calibrator Level 1

Hazard Codes

Hazard statements (CLP)

H317, H411

Hazard statements

Code

Statements

H317

May cause an allergic skin reaction

H411

Toxic to aquatic life with long lasting effects

Section 2

SECTION 2: Hazards identification

Classification of the substance or mixture

Product definition

RCRP Calibrator Level 1 Mixture RCRP Calibrator Levels 2-5 Mixture Classification according to UK CLP/GHS RCRP Calibrator Level 1 Skin Sens. 1, H317 Aquatic Chronic 2, H411 RCRP Calibrator Levels 2-5 Skin Sens. 1, H317 Aquatic Chronic 2, H411

Signal word

RCRP Calibrator Level 1 Warning RCRP Calibrator Levels 2-5 Warning

Hazard statements

RCRP Calibrator Level 1 H317 - May cause an allergic skin reaction. H411 - Toxic to aquatic life with long lasting effects. RCRP Calibrator Levels 2-5 H317 - May cause an allergic skin reaction. H411 - Toxic to aquatic life with long lasting effects.

Prevention

RCRP Calibrator Level 1 P280 - Wear protective gloves/protective clothing/eye protection/face protection. P273 - Avoid release to the environment. RCRP Calibrator Levels 2-5 P280 - Wear protective gloves/protective clothing/eye protection/face protection. P273 - Avoid release to the environment.

Response

RCRP Calibrator Level 1 P302 + P352 - IF ON SKIN: IF ON SKIN: Wash with plenty of soap and water. P333 + P313 - If skin irritation or rash occurs: If skin irritation or rash occurs: Get medical advice/attention. P362 + P364 - Take off contaminated clothing and wash it before reuse. P391 - Collect spillage. RCRP Calibrator Levels 2-5 P302 + P352 - IF ON SKIN: IF ON SKIN: Wash with plenty of soap and water. P333 + P313 - If skin irritation or rash occurs: If skin irritation or rash occurs: Get medical advice/attention. P362 + P364 - Take off contaminated clothing and wash it before reuse. P391 - Collect spillage.

Storage

RCRP Calibrator Level 1 Not applicable. RCRP Calibrator Levels 2-5 Not applicable.

Disposal

RCRP Calibrator Level 1 P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations. RCRP Calibrator Levels 2-5 P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.

Supplemental label elements

RCRP Calibrator Level 1 Not applicable. elements RCRP Calibrator Levels 2-5 Not applicable. Annex XVII - Restrictions RCRP Calibrator Level 1 Not applicable. on the manufacture, RCRP Calibrator Levels 2-5 Not applicable. placing on the market and use of certain dangerous substances, mixtures and articles

2.3 Other hazards

Product meets the criteria RCRP Calibrator Level 1 This mixture does not contain any for PBT or vPvB according substances that are assessed to be a to Regulation (EC) No. PBT or a vPvB.

Additional information

Potentially biohazardous material. Sodium azide may react with lead or copper plumbing to form highly explosive metal azides.

2.1 Classification of the substance or mixture

Product definition : RCRP Calibrator Level 1 Mixture RCRP Calibrator Levels 2-5 Mixture Classification according to UK CLP/GHS RCRP Calibrator Level 1 Skin Sens. 1, H317 Aquatic Chronic 2, H411 RCRP Calibrator Levels 2-5 Skin Sens. 1, H317 Aquatic Chronic 2, H411 The product is classified as hazardous according to UK CLP Regulation SI 2019/720 as amended. See Section 16 for the full text of the H statements declared above. See Section 11 for more detailed information on health effects and symptoms.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.