Note: Ingredients listed on restricted chemical lists
EC/CAS
247-852-1/26628-22-8
Name of the chemical
Sodium Azide
Concentration
<0.1
General Information
Revision date
2022-12-13
Product name
Atellica CH Alanine Aminotransferase (ALT)
1.2.1 Relevant identified uses
ALT Reagent 1 Diagnostic agents ALT Reagent 2 Diagnostic agents
supplier name
Siemens Healthcare Diagnostics Limited
Emergency telephone
+44 20 3807 3798
Icons in SDS
Company Information
company name
Siemens Healthcare Diagnostics Limited
e-mail address of the competent person responsible for the Safety Data Sheet
dx.msds.healthcare@siemens-healthineers.com
GHS Information
Signal word
ALT Reagent 1
Hazard Codes
Hazard statements (CLP)
H319
Hazard statements
Code
Statements
H319
Causes serious eye irritation
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture
Product definition
ALT Reagent 1 Mixture ALT Reagent 2 Mixture Classification according to UK CLP/GHS ALT Reagent 2 Eye Irrit. 2, H319
Signal word
ALT Reagent 1 No signal word. ALT Reagent 2 Warning
Hazard statements
ALT Reagent 1 No known significant effects or critical hazards. ALT Reagent 2 H319 - Causes serious eye irritation.
Prevention
ALT Reagent 1 Not applicable. ALT Reagent 2 P280 - Wear protective gloves/protective clothing/eye protection/face protection.
Response
ALT Reagent 1 Not applicable. ALT Reagent 2 P337 + P313 - If eye irritation persists: Get medical advice/attention.
Storage
ALT Reagent 1 Not applicable. ALT Reagent 2 Not applicable.
Disposal
ALT Reagent 1 Not applicable. ALT Reagent 2 Not applicable.
Supplemental label elements
ALT Reagent 1 Not applicable. elements ALT Reagent 2 Not applicable. Annex XVII - Restrictions ALT Reagent 1 Not applicable. on the manufacture, ALT Reagent 2 Not applicable. placing on the market and use of certain dangerous substances, mixtures and articles
2.3 Other hazards
Product meets the criteria ALT Reagent 1 This mixture does not contain any for PBT or vPvB according substances that are assessed to be a to Regulation (EC) No. PBT or a vPvB.
Additional information
Not available. Sodium azide may react with lead or copper plumbing to form highly explosive metal azides.
2.1 Classification of the substance or mixture
Product definition : ALT Reagent 1 Mixture ALT Reagent 2 Mixture Classification according to UK CLP/GHS ALT Reagent 2 Eye Irrit. 2, H319 The product is not classified as hazardous according to UK CLP Regulation SI 2019/720 as amended. See Section 16 for the full text of the H statements declared above. See Section 11 for more detailed information on health effects and symptoms.