Note: Ingredients listed on restricted chemical lists
EC/CAS
9002-93-1
Name of the chemical
Octylphenolethoxylates (OPEO)
Concentration
N/A
EC/CAS
220-239-6/55965-84-9
Name of the chemical
Mixture of 5-chloro-2-methyl-2H- isothiazol-3-one (EINECS 247-500-7) and 2-methyl-2H-isothiazol-3-one (EINECS 220-239-6)
Concentration
N/A
EC/CAS
247-500-7/67-56-1
Name of the chemical
Methanol
Concentration
N/A
General Information
Revision date
2020-04-01
Product name
HEMA-TEK (WRIGHT-GIEMSA) STAIN PAK
Icons in SDS
Company Information
company name
Siemens Healthcare Diagnostics Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H301+H311+H331, H302, H317, H370, H371
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
29 CFR 1910.1200) OSHA/HCS status : HEMA-TEK (WRIGHT-GIEMSA) BUFFER While this material is not considered SOLUTION hazardous by the OSHA Hazard Communication Standard (29 CFR 1910. 1200), this SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and available for employees and other users of this product. HEMA-TEK (WRIGHT-GIEMSA) RINSE This material is considered hazardous by SOLUTION the OSHA Hazard Communication Standard (29 CFR 1910.1200). HEMA-TEK (WRIGHT-GIEMSA) STAIN This material is considered hazardous by SOLUTION the OSHA Hazard Communication Standard (29 CFR 1910.1200). Classification of the HEMA-TEK (WRIGHT-GIEMSA) BUFFER Not classified. substance or mixture SOLUTION HEMA-TEK (WRIGHT-GIEMSA) RINSE ACUTE TOXICITY (oral) - Category 4 SOLUTION SKIN SENSITIZATION - Category 1 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) - Category 2 HEMA-TEK (WRIGHT-GIEMSA) STAIN FLAMMABLE LIQUIDS - Category 2 SOLUTION ACUTE TOXICITY (oral) - Category 3 ACUTE TOXICITY (dermal) - Category 3 ACUTE TOXICITY (inhalation) - Category 3 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) - Category 1
Additional information
Not available.
Signal word
HEMA-TEK (WRIGHT-GIEMSA) BUFFER No signal word. SOLUTION HEMA-TEK (WRIGHT-GIEMSA) RINSE Warning SOLUTION HEMA-TEK (WRIGHT-GIEMSA) STAIN Danger SOLUTION
Hazard statements
HEMA-TEK (WRIGHT-GIEMSA) BUFFER No known significant effects or critical SOLUTION hazards. HEMA-TEK (WRIGHT-GIEMSA) RINSE H302 - Harmful if swallowed. SOLUTION H317 - May cause an allergic skin reaction. H371 - May cause damage to organs. HEMA-TEK (WRIGHT-GIEMSA) STAIN H225 - Highly flammable liquid and vapor. SOLUTION H301 + H311 + H331 - Toxic if swallowed, in contact with skin or if inhaled. H370 - Causes damage to organs.
Prevention
HEMA-TEK (WRIGHT-GIEMSA) BUFFER Not applicable. SOLUTION HEMA-TEK (WRIGHT-GIEMSA) RINSE P260 - Do not breathe vapor. SOLUTION P264 - Wash hands thoroughly after handling. P280 - Wear protective gloves/protective clothing/eye protection/face protection. P272 - Contaminated work clothing should not be allowed out of the workplace. HEMA-TEK (WRIGHT-GIEMSA) STAIN P280 - Wear protective gloves/protective SOLUTION clothing/eye protection/face protection. P210 - Keep away from heat, sparks, open flames and hot surfaces. - No smoking. P260 - Do not breathe vapor. P235 - Keep cool.
Response
HEMA-TEK (WRIGHT-GIEMSA) BUFFER Not applicable. SOLUTION HEMA-TEK (WRIGHT-GIEMSA) RINSE P308 + P311 - IF exposed or concerned: SOLUTION Call a POISON CENTER or physician. P301 + P312 + P330 - IF SWALLOWED: Call a POISON CENTER or physician if you feel unwell. Rinse mouth. P302 + P352 + P363 - IF ON SKIN: Wash with plenty of soap and water. Wash contaminated clothing before reuse. P333 + P313 - If skin irritation or rash occurs: Get medical attention. HEMA-TEK (WRIGHT-GIEMSA) STAIN P304 - IF INHALED: SOLUTION P340 - Remove victim to fresh air and keep at rest in a position comfortable for breathing. P301 - IF SWALLOWED: P310 - Immediately call a POISON CENTER or physician. P303 - IF ON SKIN (or hair): P361 - Take off immediately all contaminated clothing. P353 - Rinse skin with water or shower.
Storage
HEMA-TEK (WRIGHT-GIEMSA) BUFFER Not applicable. SOLUTION HEMA-TEK (WRIGHT-GIEMSA) RINSE P405 - Store locked up. SOLUTION HEMA-TEK (WRIGHT-GIEMSA) STAIN Not applicable. SOLUTION
Disposal
HEMA-TEK (WRIGHT-GIEMSA) BUFFER Not applicable. SOLUTION HEMA-TEK (WRIGHT-GIEMSA) RINSE P501 - Dispose of contents and container SOLUTION in accordance with all local, regional, and national regulations. HEMA-TEK (WRIGHT-GIEMSA) STAIN P501 - Dispose of contents and container SOLUTION in accordance with all local, regional, and national regulations.
Supplemental label elements
HEMA-TEK (WRIGHT-GIEMSA) BUFFER None known. elements SOLUTION HEMA-TEK (WRIGHT-GIEMSA) RINSE None known. SOLUTION HEMA-TEK (WRIGHT-GIEMSA) STAIN None known. SOLUTION Hazards not otherwise : HEMA-TEK (WRIGHT-GIEMSA) BUFFER None known. classified SOLUTION HEMA-TEK (WRIGHT-GIEMSA) RINSE None known. SOLUTION HEMA-TEK (WRIGHT-GIEMSA) STAIN None known. SOLUTION