Note: Ingredients listed on restricted chemical lists
EC/CAS
247-500-7/55965-84-9
Name of the chemical
Mixture of 5-chloro-2-methyl-2H- isothiazol-3-one (EINECS 247-500-7) and 2-methyl-2H-isothiazol-3-one (EINECS 220-239-6)
Concentration
0.00297
EC/CAS
220-239-6/26628-22-8
Name of the chemical
Sodium Azide
Concentration
0.094
General Information
Version
1.07
Revision date
2020-12-16
Product name
Emit 2000 Valproic Acid Assay
Icons in SDS
Company Information
company name
Siemens Healthcare Diagnostics Inc
GHS Information
Signal word
Emit® 2000 Valproic Acid Assay, Reagent 1 Warning
Hazard Codes
Hazard statements (CLP)
H317
Hazard statements
Code
Statements
H317
May cause an allergic skin reaction
Section 2
SECTION 2: Hazards identification
Signal word
Emit® 2000 Valproic Acid Assay, Reagent 1 Warning Emit® 2000 Valproic Acid Assay, Reagent 2 No signal word.
Hazard statements
Emit® 2000 Valproic Acid Assay, Reagent 1 H317 - May cause an allergic skin reaction. Emit® 2000 Valproic Acid Assay, Reagent 2 No known significant effects or critical hazards.
Prevention
Emit® 2000 Valproic Acid Assay, Reagent 1 P272 - Contaminated work clothing should not be allowed out of the workplace. P280 - Wear protective gloves/protective clothing/eye protection/face protection. Emit® 2000 Valproic Acid Assay, Reagent 2 Not applicable.
Response
Emit® 2000 Valproic Acid Assay, Reagent 1 P302 + P352 + P363 - IF ON SKIN: Wash with plenty of soap and water. Wash contaminated clothing before reuse. P333 + P313 - If skin irritation or rash occurs: Get medical attention. Emit® 2000 Valproic Acid Assay, Reagent 2 Not applicable.
Storage
Emit® 2000 Valproic Acid Assay, Reagent 1 Not applicable. Emit® 2000 Valproic Acid Assay, Reagent 2 Not applicable.
Disposal
Emit® 2000 Valproic Acid Assay, Reagent 1 P501 - Dispose of contents and container in accordance with all local, regional, and national regulations. Emit® 2000 Valproic Acid Assay, Reagent 2 Not applicable.
Supplemental label elements
Emit® 2000 Valproic Acid Assay, Reagent 1 None known. elements Emit® 2000 Valproic Acid Assay, Reagent 2 None known.
2.3 Other hazards
Emit® 2000 Valproic Acid Assay, Reagent 1 None known. Emit® 2000 Valproic Acid Assay, Reagent 2 None known.
2.1 Classification of the substance or mixture
Emit® 2000 Valproic Acid Assay, Reagent 1 SKIN SENSITIZATION - Category 1 substance or mixture Emit® 2000 Valproic Acid Assay, Reagent 2 Not classified. Additional information : Not available. Sodium azide may react with lead or copper plumbing to form highly explosive metal azides.