Note: Ingredients listed on restricted chemical lists
EC/CAS
50-00-0
Name of the chemical
Formaldehyde
Concentration
N/A
General Information
Revision date
2016-01-22
Product name
ADVIA Chemistry ISE Buffer
CAS No.
50-00-0
Icons in SDS
Company Information
company name
Siemens Healthcare Diagnostics Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H317, H350
Hazard statements
Code
Statements
H317
May cause an allergic skin reaction
Section 2
SECTION 2: Hazards identification
29 CFR 1910.1200) OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).
2.1 Classification of the substance or mixture
SKIN SENSITIZATION - Category 1 CARCINOGENICITY - Category 1A
Signal word
Danger
Hazard statements
H317 - May cause an allergic skin reaction. H350 - May cause cancer.
Prevention
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P261 - Avoid breathing vapor. P280 - Wear protective gloves/protective clothing/eye protection/face protection. P272 - Contaminated work clothing should not be allowed out of the workplace.
Response
P308 + P313 - IF exposed or concerned: Get medical attention. P302 + P352 + P363 - IF ON SKIN: Wash with plenty of soap and water. Wash contaminated clothing before reuse. P333 + P313 - If skin irritation or rash occurs: Get medical attention.
Storage
Not applicable.
Disposal
P501 - Dispose of contents and container in accordance with all local, regional, and national regulations.
2.3 Other hazards
None known.