GHS08
Health risk rating 4
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

14808-60-7

Name of the chemical

Silica, crystalline

Concentration

N/A

EC/CAS

238-878-4

Name of the chemical

Quarz-A-Staub (s. u. TRGS 906)

Concentration

N/A

General Information

Revision date

2010-10-08

Product name

SILVERBOND M6 / M8 / M10 / M300 / M400

Product Synonyms

Silica flour; crystalline silica flour; silicon dioxide ;

CAS No.

14808-60-7

REACH No

Exempted

1.2.1 Relevant identified uses

Paints and coatings, cementitious systems, epoxy, electrical assemblies, potting compounds, thermal insulating,…

Emergency telephone

Available outside office hours ?

Icons in SDS

GHS08

Company Information

company name

SIBELCO BENELUX

e-mail address of the competent person responsible for the Safety Data Sheet

sales@sibelco.be

GHS Information

Signal word

Warning

Hazard Codes

Hazard statements (CLP)

H373

Hazard statements

Code

Statements

H373

May cause damage to organs through prolonged or repeated exposure

Section 2

2.1 Classification of the substance or mixture

This product contains respirable quartz as an impurity and therefore is classified as STOT RE2 according to criteria defined in the Regulation EC 1272/2008 and does not meet the criteria for classification as harmful according to Directive 67/548/EEC. Depending on the type of handling and use (e.g. grinding, drying), airborne respirable crystalline silica may be generated. Prolonged and/or massive inhalation of respirable crystalline silica dust may cause lung fibrosis, commonly referred to as silicosis. Principal symptoms of silicosis are cough and breathlessness. Occupational exposure to respirable crystalline silica dust should be monitored and controlled. This product should be handled with care to avoid dust generation. Regulation EC 1272/2008: WARNING STOT RE2 H373: May cause damage to lung through prolonged or repeated exposure by inhalation.

67/548/EEC

No classification This product contains respirable crystalline silica between 1 and 10%.

Signal word

WARNING

Hazard statements

H373: May cause damage to lung through prolonged or repeated exposure by inhalation.

Precautionary statements

P260 Do not breathe dust P285: In case of inadequate ventilation wear respiratory protection. P501: Dispose of contents/containers in accordance with local regulation.

2.3 Other hazards

This product is an inorganic susbstance and does not meet the criteria for PBT or vPvB in accordance with Annex XIII of REACh.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.