General Information
Version
2.2
Revision date
2023-05-01
Product name
GTL BO3
CAS No.
848301-69-9
REACH No
01-0000020163-82
1.2.1 Relevant identified uses
Base oil
Emergency telephone
+44 (0) 20 7934 7778, +31(0)88 755
Icons in SDS
Company Information
company name
Shell Trading Rotterdam B.V
e-mail address of the competent person responsible for the Safety Data Sheet
TRsds@shell.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H304
Hazard statements
Code
Statements
H304
May be fatal if swallowed and enters airways
Section 2
SECTION 2: Hazards identification
Regulation (EC) No. 1272/2008 Classification of the substance or mixture
Signal word
Danger
Physical hazards
Not classified as a physical hazard according to CLP criteria.
Health hazards
H304 May be fatal if swallowed and enters airways.
Environmental hazards
Not classified as environmental hazard according to CLP criteria.
Prevention
No precautionary phrases.
Response
P331 Do NOT induce vomiting. P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
Storage
P405 Store locked up.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
2.3 Other hazards
The substance does not fulfill all screening criteria for persistence, bioaccumulation and toxicity and hence is not considered to be PBT or vPvB.
ECOLOGICAL INFORMATION
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regu- lation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
TOXICOLOGICAL INFORMATION
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. May ignite on surfaces at temperatures above auto-ignition temperature. Vapour in the headspace of tanks and containers may ignite and explode at temperatures ex- ceeding auto-ignition temperature, where vapour concentrations are within the flammability range. This material is a static accumulator. Even with proper grounding and bonding, this material can still accumulate an electrostatic charge. If sufficient charge is allowed to accumulate, electrostatic discharge and ignition of flammable air- vapour mixtures can occur. Electrostatic charges may be generated during pumping. Electrostatic discharge may cause fire.
2.1 Classification of the substance or mixture
Classification (REGULATION (EC) No 1272/2008) Aspiration hazard, Category 1 H304: May be fatal if swallowed and enters air- ways.