General Information
Revision date
2017-03-20
Product name
Tetramer
Product Synonyms
Olefin Mixture C5-C15
CAS No.
68783-10-8
1.2.1 Relevant identified uses
Chemical intermediate., Use only in industrial processes
Emergency telephone
+44 (0) 1235 239 670
Icons in SDS
Company Information
company name
Shell (Switzerland)
e-mail address of the competent person responsible for the Safety Data Sheet
sccmsds@shell.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H304, H400, H410
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
Flammable liquids, Category 3 H226: Flammable liquid and vapour. Aspiration hazard, Category 1 H304: May be fatal if swallowed and enters airways. Acute aquatic toxicity, Category 1 H400: Very toxic to aquatic life. Chronic aquatic toxicity, Category 1 H410: Very toxic to aquatic life with long lasting effects.
2.2 Label elements
REGULATION (EC) No 1272/2008)
Signal word
Danger
Physical hazards
H226 Flammable liquid and vapour.
Health hazards
H304 May be fatal if swallowed and enters airways.
Environmental hazards
H400 Very toxic to aquatic life. H410 Very toxic to aquatic life with long lasting effects.
Supplemental label elements
EUH066 Repeated exposure may cause skin
Hazard statements
dryness or cracking.
Prevention
P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking. P243 Take precautionary measures against static discharge. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P370 + P378 In case of fire: Use appropriate media to extinguish. P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor. P331 Do NOT induce vomiting.
2.3 Other hazards
The substance does not fulfill all screening criteria for persistence, bioaccumulation and toxicity and hence is not considered to be PBT or vPvB. This material is a static accumulator. Even with proper grounding and bonding, this material can still accumulate an electrostatic charge. If sufficient charge is allowed to accumulate, electrostatic discharge and ignition of flammable air- vapour mixtures can occur. Vapours are heavier than air. Vapours may travel across the ground and reach remote ignition sources causing a flashback fire danger. Will float and can be reignited on surface water.