General Information
Revision date
2021-01-06
Product name
Ethyl PROXITOL
Product Synonyms
EP, PGEE
CAS No.
1569-02-4
REACH No
01-2119462792-32-0001
1.2.1 Relevant identified uses
Solvent
Emergency telephone
+44 (0) 1235 239 670 (This telephone number is available 24 hours per day, 7 days per week
Icons in SDS
Company Information
company name
Shell (Switzerland)
e-mail address of the competent person responsible for the Safety Data Sheet
sccmsds@shell.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H226, H319, H336
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
Flammable liquids, Category 3 H226: Flammable liquid and vapour. Eye irritation, Category 2 H319: Causes serious eye irritation. Specific target organ toxicity - single H336: May cause drowsiness or dizziness. exposure, Category 3, Narcotic effects
2.2 Label elements
REGULATION (EC) No 1272/2008)
Signal word
Warning
Physical hazards
H226 Flammable liquid and vapour.
Health hazards
H319 Causes serious eye irritation. H336 May cause drowsiness or dizziness.
Environmental hazards
Not classified as environmental hazard according to CLP criteria.
Prevention
P210 Keep away from heat/ sparks/ open flames/ hot surfaces. No smoking. P243 Take precautionary measures against static discharge. P264 Wash hands thoroughly after handling. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 If eye irritation persists: Get medical advice/ attention.
Storage
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
2.3 Other hazards
The substance does not fulfill all screening criteria for persistence, bioaccumulation and toxicity and hence is not considered to be PBT or vPvB. Vapours are heavier than air. Vapours may travel across the ground and reach remote ignition sources causing a flashback fire danger. Even with proper grounding and bonding, this material can still accumulate an electrostatic charge. If sufficient charge is allowed to accumulate, electrostatic discharge and ignition of flammable air- vapour mixtures can occur.