Note: Ingredients listed on restricted chemical lists
EC/CAS
203-632-7/108-95-2
Name of the chemical
Phenol
Concentration
<=100
General Information
Revision date
2021-11-03
Product name
Phenol
CAS No.
108-95-2
REACH No
01-2119471329-32-0001
1.2.1 Relevant identified uses
Use as an intermediate in industrial chemicals manufacture Please refer to section 16 and/or the annexes for the regis- tered uses under REACH
Emergency telephone
+44 (0) 1235 239 670
Icons in SDS
Company Information
company name
Shell Chemicals Europe B.V
e-mail address of the competent person responsible for the Safety Data Sheet
sccmsds@shell.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H301, H311, H314, H318, H331, H341, H373
Hazard statements
Code
Statements
H301
Toxic if swallowed
Section 2
2.1 Classification of the substance or mixture
Classification
Signal word
Danger
Physical hazards
Not classified as a physical hazard according to CLP criteria.
Health hazards
H301 Toxic if swallowed. H311 Toxic in contact with skin. H331 Toxic if inhaled. H314 Causes severe skin burns and eye damage. H341 Suspected of causing genetic defects. H373 May cause damage to organs (Kidney, Liver, Skin, Respiratory system, Heart) through prolonged or repeated exposure.
Environmental hazards
Not classified as environmental hazard according to CLP criteria.
Prevention
P260 Do not breathe dust/ fume/ gas/ mist/ vapours/ spray. P280 Wear protective gloves/ protective clothing/ eye protec- tion/ face protection.
Response
P302 + P352 IF ON SKIN: Wash with plenty of water and soap. P305 + P351 + P338 IF IN EYES: Rinse cautiously with wa- ter for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
Storage
No precautionary phrases.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
2.3 Other hazards
Risk of explosion if heated under confinement. Even with proper grounding and bonding, this material can still accumulate an electrostatic charge. If sufficient charge is allowed to accumulate, electrostatic discharge and ignition of flammable air- vapour mixtures can occur.