General Information
Revision date
2021-11-03
Product name
NEODENE 8/9/10 Internal Olefin
CAS No.
68526-55-6
REACH No
01-2119480441-43-0000
1.2.1 Relevant identified uses
Chemical intermediate Please refer to section 16 and/or the annexes for the regis- tered uses under REACH
Icons in SDS
Company Information
company name
Shell Chemicals Europe B.V
e-mail address of the competent person responsible for the Safety Data Sheet
sccmsds@shell.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H304, H400, H410
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
Flammable liquids, Category 3 H226: Flammable liquid and vapour. Aspiration hazard, Category 1 H304: May be fatal if swallowed and enters air- ways. Short-term (acute) aquatic hazard, Cate- H400: Very toxic to aquatic life. gory 1 Long-term (chronic) aquatic hazard, Cat- H410: Very toxic to aquatic life with long lasting egory 1 effects.
2.2 Label elements
REGULATION (EC) No 1272/2008)
Signal word
Danger
Physical hazards
H226 Flammable liquid and vapour.
Health hazards
H304 May be fatal if swallowed and enters airways.
Environmental hazards
H400 Very toxic to aquatic life. H410 Very toxic to aquatic life with long lasting effects.
Supplemental label elements
EUH066 Repeated exposure may cause skin
Hazard statements
dryness or cracking.
Prevention
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P243 Take action to prevent static discharges. P273 Avoid release to the environment.
Response
P303 + P361 + P353 IF ON SKIN (or hair): Take off immedi- ately all contaminated clothing. Rinse skin with water/ shower. P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor. P331 Do NOT induce vomiting. P391 Collect spillage.
Storage
No precautionary phrases.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
2.3 Other hazards
The substance does not fulfill all screening criteria for persistence, bioaccumulation and toxicity and hence is not considered to be PBT or vPvB. Vapours are heavier than air. Vapours may travel across the ground and reach remote ignition sources causing a flashback fire danger. Will float and can be reignited on surface water. This material is a static accumulator. Even with proper grounding and bonding, this material can still accumulate an electrostatic charge. If sufficient charge is allowed to accumulate, electrostatic discharge and ignition of flammable air- vapour mixtures can occur.