GHS02 GHS04 GHS08
Health risk rating 4
Safety risk rating 4
Environmental risk rating 3

Note: Ingredients listed on restricted chemical lists

EC/CAS

106-97-8

Name of the chemical

n-Butan, enthält  0,1% Butadien

Concentration

N/A

EC/CAS

109-66-0

Name of the chemical

pentane

Concentration

N/A

EC/CAS

110-54-3

Name of the chemical

n-Hexan (790/2009)

Concentration

N/A

EC/CAS

106-99-0

Name of the chemical

1,3-Butadien

Concentration

N/A

General Information

Revision date

2021-09-22

Product name

NGL C2+ Mix

Emergency telephone

(24 hr

Icons in SDS

Company Information

company name

Shell Chemicals Canada

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H220, H280, H304, H361, H412

Hazard statements

Code

Statements

H220

Extremely flammable gas

Section 2

2.1 Classification of the substance or mixture

Flammable gases : Category 1 Gases under pressure : Compressed gas Reproductive toxicity : Category 2

Aspiration hazard

Category 1 Long-term (chronic) aquatic : Category 3

Signal word

Danger

Physical hazards

H220 Extremely flammable gas. H280 Contains gas under pressure; may explode if heated.

Health hazards

H361 Suspected of damaging fertility or the unborn child. H304 May be fatal if swallowed and enters airways.

Environmental hazards

H412 Harmful to aquatic life with long lasting effects.

Prevention

P210 Keep away from heat/ sparks/ open flames/ hot surfaces. No smoking. P243 Take precautionary measures against static discharge. P280 Wear protective gloves/ eye protection/ face protection.

Response

P304 + P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Storage

P403 Store in a well-ventilated place.

Other hazards which do not result in classification

Electrostatic charges may be generated during pumping. Electrostatic discharge may cause fire. Vapours are heavier than air. Vapours may travel across the ground and reach remote ignition sources causing a flashback fire danger. This material has the potential to be a static accumulator.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.