Note: Ingredients listed on restricted chemical lists
EC/CAS
106-97-8
Name of the chemical
n-Butan, enthält 0,1% Butadien
Concentration
10-30
EC/CAS
110-54-3
Name of the chemical
n-Hexan (790/2009)
Concentration
1-5
EC/CAS
106-99-0
Name of the chemical
1,3-Butadien
Concentration
<0.1
General Information
Version
3.1
Revision date
2025-05-29
Product name
NGL C2+ Mix
1.2.1 Relevant identified uses
Used as a domestic, commercial, industrial and automotive fuel, a feedstock in chemical processes
Emergency telephone
1-800-424-9300
Icons in SDS
Company Information
company name
Shell Chemicals Canada
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280, H304, H361, H412
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Flammable gases : Category 1A Gases under pressure : Compressed gas Reproductive toxicity : Category 2 Aspiration hazard : Category 1 Long-term (chronic) aquatic : Category 3 hazard
Aspiration hazard
Category 1 Long-term (chronic) aquatic Category 3 hazard
Signal word
Danger
Physical hazards
H220 Extremely flammable gas H280 Contains gas under pressure; may explode if heated
Health hazards
H304 May be fatal if swallowed and enters airways H361 Suspected of damaging fertility or the unborn child
Environmental hazards
H412 Harmful to aquatic life with long lasting effects
Prevention
P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P243 Take precautionary measures against static discharge. P273 Avoid release to the environment. P280 Wear protective gloves/ eye protection/ face protection.
Response
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor. P304 + P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P308 + P313 IF exposed or concerned: Get medical advice/ attention. P331 Do NOT induce vomiting. P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P381 In case of leakage, eliminate all ignition sources.
Storage
P403 Store in a well-ventilated place. P405 Store locked up. P410 + P403 Protect from sunlight. Store in a well-ventilated place.
Disposal
P501 Dispose of contents and container to an approved waste disposal plant.
Other hazards which do not result in classification
Electrostatic charges may be generated during pumping. Electrostatic discharge may cause fire. Vapours are heavier than air. Vapours may travel across the ground and reach remote ignition sources causing a flashback fire danger. This material has the potential to be a static accumulator.