General Information
Revision date
2018-04-26
Product name
Ethyl Proxitol Acetate
CAS No.
98516-30-4
1.2.1 Relevant identified uses
Speciality solvent
Emergency telephone
(24
Icons in SDS
Company Information
company name
Shell Chemical LP
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H226, H336
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
OSHA HCS Classification
Flammable liquids Category 3 Specific target organ toxicity Category 3 (Narcotic effects.) - single exposure
Signal word
Warning
Physical hazards
H226 Flammable liquid and vapour.
Health hazards
H336 May cause drowsiness or dizziness.
Environmental hazards
Not classified as an environmental hazard under GHS criteria.
Prevention
P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking. P240 Ground/bond container and receiving equipment. P241 Use explosion-proof electrical/ ventilating/ lighting equip- ment. P242 Use only non-sparking tools. P243 Take precautionary measures against static discharge. P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P370 + P378 In case of fire: Use appropriate media to extin- guish. P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P312 Call a POISON CENTER/doctor if you feel unwell.
Storage
P403 + P233 Store in a well-ventilated place. Keep container tightly closed. P235 Keep cool. P405 Store locked up.
Disposal
P501 Dispose of contents and container to appropriate waste site or reclaimer in accordance with local and national regula- tions.
Other hazards which do not result in classification
Even with proper grounding and bonding, this material can still accumulate an electrostatic charge. If sufficient charge is allowed to accumulate, electrostatic discharge and ignition of flammable air- vapour mixtures can occur. The classification of this material is based on OSHA HCS 2012 criteria.